Giandel PS-4000QAR Скачать руководство пользователя страница 5

1. High power load connection

    If the electrical appliance power is higher than a single socket max output power, please

connect it to the ac output terminal.

2. Connection of the remote control box

        Directly  to  the  two  ends  of  the  cable  respectively  inserted  into  the  inverter  and  wired 

remote control remote control box on the interface.

7. USAGE

. How to use inverter

1) Check the output voltage and capacity of the battery to make sure it is in accord with the 

requirements of the product.

2) Connect the battery and the DC cable of the inverter to ensure that the polarities are not 

connected reversely and in tight connection.

3)  Long  press  the  switch  or  the  remoter  of  inverter  for  over  0.5s  and  then  stop,  if  the 

indicator  light  on  the  inverter  or  on  the  remote  control  box  is  on,  it  means  that  the 

inverter starts to work normally. This opening method can avoid turning on the unit by 

mistakes due to the interference or any factors.

4) Switch off electrical appliances and put its plug to the AC output socket of inverter. Then 

switch on electrical appliance.

5)  The cooling fans inside the inverter do not work until the case temperature rises up to 

about 40

 or the load power is more than 40% of rated power.

6) Switch off inverter and remoter to stop working. At that time, the indicator lights in.  

Both 

inverter and remoter are off. The inverter does not consume current of the battery when 

it is switched off.

 How to use USB power supply

   This model with USB output, can provide stable voltage 5V DC, maximum current 2.4A  

directly for the portable device with USB port.

Notice: Before using the USB power supply, please make sure the device can be charged 

by USB and the maximum working current is no more than 2.4A.

6.

Notice:

(1) The table above is only for your reference. In practice, the thick wire can be replaced 

by  two  thin  parallel  wires  if  only  the  total  cross-sectional  area  of  the  wire  meets  the 
requirements.

(2) In high current, the input DC wire may produce voltage drop, therefore, the operating 

voltage should be subject to the value on the terminals. If the voltage drop is too large, 
you can increase the cross-sectional area or reduce the length of the lead. 

(3) Connect cathode wire of the battery to the cathode terminal (black) on the rear panel of 

inverter and then connect the anode wire of the battery to the anode terminal (red) on 
the inverter, and fix them.

Warnings:

(1)  Please  wear  eye  patch  and  work  clothes  when  working  around  the  battery  to  protect 

your eyes and skin from the acid and corrosive objects. 

(2) Prepare enough water and soap. In case the acid material splashes on your skin, clean 

it  by  soap  and  water  as  soon  as  possible.  If  the  acid  material  spays  to  your  eyes 
accidentally, clean it by cold water and then sent to hospital.

(3)  Do  not  put  any  combustible  material  in  the  location  of  installation  for  it  will  result  in 

spark when connected to the battery.

(4) Keep good ventilation. The battery may produce a little inflammable gas when it works, 

so keep away from the inverter and it is better to install them in different space.

(5)  Fix  the  connecting  wire  of  the  input  DC,  or  it  will  result  in  the  over-  reduction  of  the 

voltage or over-temperature of the inverter.

(6)  Reverse  connection  of  the  polarities  or  the  short  circuit  will  burn  the  fuse  or  result  in 

the permanent damage of the internal elements of inverter.

(7) Take away the metal accouterments, such as ring or watch, when installation, to avoid 

the short circuit.

(8) Although there is over-voltage protection, it may also cause damage of the inverter if 

the input voltage is too high.

3) Connection of the AC appliance

    Put the load power plug of the AC appliance into the output AC receptacle of the inverter 
directly.

Warnings:

(1)  Make  sure  that  the  switches  of  the  inverter  and  the  appliances  are  in  OFF  position 

before connection.

(2) Check the power cord. If it is damaged, it should be connected after replacement. 

(3) Connection of the AC appliance: Put the power plug of the AC appliance load into the 

output AC receptacle of the inverter directly.

Warnings:

      Make  sure  that  the  switches  of  the  inverter  and  appliance  power  are  in  OFF  position 
before connection.

      Check the power cord. If it is damaged, it should be connected after replacement.

        Each  output  socket  of  the  inverter  has  a  rating  current  given  by  manufacturer.  Don't 
exceed the value in operation, or the socket will be damaged because of over temperature 
and  it  may  cause  electric  shock.  For  the  max  output  power  of  the  single  socket,  see  the 
following tables:

Output socket

AC output voltage

Single socket 

max output current 

Single socket 

max output power 

110~120VAC

220~240VAC

220~240VAC

220~240VAC

15A

16A

13A

10A

1500W

3000W

2500W

2000W

220~240VAC

13A

2500W

Отзывы: