Giandel PM-5000QBR Скачать руководство пользователя страница 4

4.

5.

3) Installation of remote control box

 Fixed on the plane with an opening, then fix two screws directly on the position of two 

installation holes of the remote control box.

 The remote control box can also be installed on the base of 86X86mm electrical socket.
 Connect the connection between the remote control box and the inverter.

Note:

 This product can also be used as a common inverter without connecting the remote 

control box.

Battery Status

FAULT

POWER

ON/OFF

Inverter Remote

Model:R3

85mm

4.5mm

5. BATTERY

1) Current and voltage of battery The battery is used to supply the DC input voltage 

required by the product, and its rated voltage must be in line with the rated input 
voltage of the inverter, beyond the input voltage range of the inverter, and the cross 
connection will cause the product to be under voltage or under voltage protection.
At the same time, the battery must provide enough current for inverter, a small capacity 
battery is not able to drive high power appliances, in this case, usually due to excessive 
current and battery discharge the battery terminal voltage low, under voltage protection 
products appear
The simple formula for the battery current is the load power / the battery voltage. As the 
inverter itself will be part of the loss, so the actual current will be greater than this value 
of about 10%. For example: the battery voltage is 12VDC, the load power is 1000W, 
then the actual current size of the battery is about 1000W 12V

110%=91.6A

2) Battery working time

The using time of battery depends on battery capacity (AH) and the power of the 
connected load (W), the calculating method is: Time (hours) =battery capacity (AH) x 
battery output voltage (V) x efficiency rate 

 electrical power of using (W) such as the 

12V DC input inverter uses the 12V battery, if the battery capacity is 2000AH and at 
this time the inverter is driving 1000W power load, the efficiency rate is 90% when the 
battery is full, according to the formula above, the battery use time =2000(AH) / (1000 / 
12x110%) = 21.8 (Hour). This means the battery can be used for 21.8 hours.

Note: 

The above formula is the calculation result of the battery discharging rate in 20 

hours, that is, when the discharging current of 2000 Ah battery does not exceed 100A, 
the discharging time will be shortened when the discharging current exceeds this value. 
This part can refer to the battery manufacturer's specifications, and whether the battery 
is fully charged will also affect this result.

6. CONNECTION

1) Grounding

The power inverter has a terminal on the back panel marked "Grounding" or "       ". 
This is used to connect the chassis of the power inverter to the ground.
The ground terminal has already connected to the ground wire of AC output receptacle 
through the internal connecting wire. The ground terminal must be connected to the 
ground wire, which will vary depending on where the power inverter is installed. In a 
vehicle, connect the ground terminal to the chassis of the vehicle. On the ship, connect 
the ground terminal to the ship grounding system; In a fixed position, connect the 
ground terminal to the earth.

Warnings:

 To make sure the firmness of the connection. The ground wire must be 14AWG ( 

2

2.08mm ) or even larger.

 Do not operate the power inverter without connecting to ground. Electric shock hazard 

may result. 

2) Connect to the battery

 Please do all the safety precautions before connection, then check whether the battery 

voltage is in accordance with the input voltage of the inverter. Only the voltage of 
battery according with the requirements can be allowed to connect with the inverter.

 The connecting wire must be big enough to bear current, or else the inverter can not 

support big load because of voltage reduce caused by the small cross-sectional wire. 
Depending on the below table, please select the input DC wire or larger one.

Inverter Input 

voltage

Rated power

Max current 

of cable

Specification of

wire length

1m

(Cross section area)

12V

24V

1000W

1500W

2000W

2500W

3000W

4000W

5000W

1000W

1500W

2000W

2500W

3000W

4000W

5000W

100A

150A

200A

250A

300A

400A

500A

50A

75A

100A

125A

150A

200A

250A

2

6AWG(13.30mm)

2

4AWG(21.15mm)

2

3AWG(26.67mm)

2

2AWG(33.62mm)

2

1AWG(42.41mm)

2

0AWG(53.49mm)

2

00AWG(67.43mm)

2

9AWG(6.63mm)

2

7AWG(10.55mm)

2

6AWG(13.3 mm)

2

5AWG(16.77mm)

2

4AWG (21.15mm)

2

3AWG (26.67mm)

2

2AWG (33.62mm)

2

N

13.30mm

2

N

21.15mm

2

N

26.67mm

2

N

33.62mm

2

N

42.41mm

2

N

53.49mm

2

N

67.43mm

2

N

6.63mm

2

N

10.55mm

2

N

13.30mm

2

N

16.77mm

2

N

21.15mm

2

N

26.67mm

2

N

33.62mm

Specification of wire 

length

1m

(Cross section area)

Specification of wire 

length

N m

(Cross section area)

2

3AWG(26.67mm )

2

1AWG(42.41mm )

2

0AWG(53.49mm )

2

00AWG(67.43mm )

2

2

1AWG(84.82mm )

2

2

0AWG(107mm )

2

2

00AWG(135mm )

2

6AWG(13.3mm )

2

4AWG(21.15mm )

2

3AWG(26.67mm )

2

2AWG(33.62mm )

2

1AWG(42.41mm )

2

0AWG(53.49mm )

2

00AWG(67.43mm )

Notice:

1. The above table is only for your reference. In practice, the thick wire can be replaced by 

two thin parallel wires if only the total section acreage of the wire meets the 
requirements. 

Power Inverter With 

Remote Controller

Содержание PM-5000QBR

Страница 1: ...5000Watt 5000Watt Power Inverter USER S MANUAL MODEL PM 5000QBR Warning This manual contains important safety and operating instruction Please read it carefully before use the unit...

Страница 2: ...can damage these items 4 The power inverter is designedto be used with a negative groundelectrical system Don t use with positive ground electrical systems the majority of modern automobiles RVs truck...

Страница 3: ...er while the installation location must meet the following requirements Drying Do not use water orother liquids dripping on the inverter Cool a working environment temperature ofthe product is 0 40 pr...

Страница 4: ...the battery is fully charged will also affectthis result 6 CONNECTION 1 Grounding The power inverter has a terminal onthe back panel marked Grounding or This is used to connect thechassis of the power...

Страница 5: ...rter and appliance powerare in OFF position before connection 2 Check the power cord If itis damaged it should be connected afterreplacement 3 Each outlet of the inverterhas a given current rating oft...

Страница 6: ...theinput DC voltage is lower than9 8V 19 6V the buzzer will whistle intermittently to remindthat the inverter will go intothe under voltage protection Pay attention to savethe data if you are usingco...

Страница 7: ...load and let it cool naturally for 10 to 30 minutes Restart it after it resumes to normal temperature The load power is too large reduce the total load power to the range of rated power Avoid blocking...