FURTHER FUNCTIONS
Timer function
The timer function is selected with the timer-button
.
With this function a user-defined temperature for a programmable
period can be entered.
This can be very useful in case of a party, for example. Press
.
First, the time for which the time programme has been deactivated is
shown. Confirm with
OK
.
Now, the desired temperature can be set. Confirm with
OK
.
In the selected period it is not possible to change the temperature
manual, the wheel is locked.
Press MENU and unlock it.
Offset function
If the perceived temperature significantly differs from the set thermostat
temperature a temperature set up can be executed.
Press
MENU
.
Select the menu item OFFS with the selector wheel. Confirm with
OK
.
The degree setting 0,0 °C will flash on the display.
Now, set up the desired adaptation for the temperature (from -5 up to
+5°C) with the selector wheel. Confirm with
OK
.
The temperature display does not change!
Open Window function
If a window is open and consequently the temperature drops
significantly, the K470H will automatically close the heating valve in
order to save energy.
The display will show .
Afterwards, the chronothermostat will resume normal operation.
For the set up select WINW in the menu. Confirm with
OK
.
First, the sensibility is selected with the selector wheel (HIGH = high
sensibility, MID = medium sensibility (factory preset), LOW = low
sensibility). Confirm with
OK
.
Now, you enter the time (10 min (factory preset) - 60 min) for which the
valve should remain closed.
Confirm with
OK
.
Travel function
For the time you are absent you can select an individual temperature.
After this period the originally defined programme becomes active
again. Press
MENU
. Select the menu item HOLY.
Confirm with
OK
, (suitcase
appears on the display).
Select with the selector wheel the end of the travel function
(= date of the recommencement of the regular heating times).
Confirm with
OK
. Set the time and confi rm with the button
OK
.
The signal OFF appears on the display.
Now set the temperature and confirm with
OK
.
The
appears on the display.
With
MENU
the function can be deactivated.
Children Lock function
You can lock the chonothermostat to protect the device from
unauthorized activation.
Press the buttons
OK
+
at the same time for about 2 seconds
until the signal appears on the display in order to lock the device.
By using this button combination again the symbol disappears and you
release the lock.
Heating Pause – Closing the valve
Press
MENU
.
Select the menu item MODE with the selector wheel.
Confirm with
OK
.
Select MANU and confirm with
OK
.
Set the temperature on the display to OFF.
The valve is now closed and will work without a time programme.
The calcification protection function remains active once a week.
After the heating pause you switch in the menu to the AUTO-mode and
the personally set programme will be executed again.
Daylight saving time
Press
MENU
.
Select DST with the selector wheel.
Confirm with
OK
and select ON/OFF with the selector wheel.
The chonothermostat switches automaticly from summer to winter time.
LCD stand-by indicator
Press
MENU
.
the menu item STBY with the selector wheel.
Confirm with the
OK
button and select ON/OFF with the selector wheel.
After about 30 seconds, the LCD indicator switches into standby mode.
By pressing any button, the display will be activated again (by removing
the battery, stand-by mode will be reseted).
Standby function Increases the battery life time.
Going back to factory preset/All reset
Press
MENU
.
Select the menu item RES with the selector wheel.
Confirm with
OK
.
OK flashes, confirm with
OK
.
The K470H is reset again.
Now, proceed as described for the initial operation.
Freeze protection and calcification protection function are
active automatically:
- Anti-Freeze protection function
If the temperature drops below 6 °C, the K470H opens the valve until the
temperature again rises above 8 °C.
This prevents the radiators from freezing.
- Calcification protection function
To prevent radiator valves from calcifying the K470H is submitted to a
calcification protection programme once a week on Friday mornings.
CLEANING AND USED DEVICES
Cleaning
To clean the K470H use only a dry or lightly wet cloth.
Avoid chemical solvent – it can probably damage the device.
Used devices
Do not throw old devices and packaging into the household waste.
They can be recycled. You receive further information at your local
government.
PROGRAMMING VIA K471 KEY
The K470H chronothermostat
can be directly programmed
via the K471 programming key,
ensuring quick and easy chron-
othermostat configuration
thanks to the exchange of data
via the Mini-USB connector.
Using the key K471 and viewing the graphic interface on the PC, you
can easily programme the daily time bands for the comfort (Tmax) and
economy (Tmin) temperatures of the chronothermostat.
Once the temperature profiles of the various rooms have been stored
on the K471 programming key, they can be uploaded onto the K470H
chronothermostat which thus automatically acquires the current time
and date.
This means that any pre-setting by the user is superfluous.
For the programming, refer to the instructions enclosed with the K471
programming key.
The device’s Mini-USB connector is only compatible with the cable
of the programmer K471; do not connect any other devices fitted
with a Mini-USB connection, as this could irreversibly damage the
chronothermostat.
TECHNICAL DATA
• No. of programmable time bands: 4 daily time bands
• Regulation type: PID with answer time lower than 3 minutes
• Power supply: 2 batteries 1,5 V, AA type
• Protection degree: IP30
• Working temperature: 0÷50 °C
• Storage temperature: -20÷70 °C
• Type of casing: white ABS
• Valve connection: M30x1,5 mm (with R453HY012 adaptor for other
Giacomini valve bodies, except DB series valves)
• Serial port to K471 programming key: proprietary interface and protocol
• Dimensions: 52 x 86 x 65 mm
• Compliance with Directive 2004/108/EC.
HELP
Problem
Cause
Solution
Batteries do not have
enough power.
Replace batteries.
Heating
element
does not
warm up.
Is the boiler water
temperature O.K.?
Valve does not open,
is it calcifi ed after
the summer pause /
heating pause?
Adjust the temperature
of the boiler water.
Remove the K470H,
move the valve
stem back and forth per
hand or with a tool.
Heating ele-
ment
does
not cool
down.
Valve does not close
completely. It may be
that the closing point
of your valve seat has
shifted.
Adapt again (see
“Adapting”) Move the
valve stem several times
by hand, it may be that
adaptation is impossible
because your valve is
calcifi ed or the seat
no longer performs its
function.
Pressure
piece falls
out (This can
also cause
an E1-error)
Due to an endlessthread
the pressure piece,
which is situated at the
bottom, can fall out if
the device has not been
affixed on the valve.
Put in the pressure
piece. The device can
beadapted by pressing
the
MEN
- point or by
removing and inserting
the batteries. The end-
lessthread is rotating
now and fi xes the pres-
sure piece again. Just
install it to the radiator
and adapt
it once again.
-
By pressing any key the error message will be
deleted in the display and the K470H is re-started.
No adaptation possible.
K470H is not installed to
the heater.
Is the installation OK?
Install the K470H to the
heater.
Valve stroke is too
short.
Open and close the
valve several times
manually or replace the
batteries.
Motor movement is
not possible.
Does the valve stem
move freely?
047U58088
11-2020
Giacomini S.p.A.
Via per alzo, 39
28017 San Maurizio d’Opaglio, Novara
+39 0322 923372
www.giacomini.com
Prodotto progettato per Giacomini S.p.A. da Et.
IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT
This product falls into the scope of the Directive 2012/19/EU concerning the management of
Waste Electrical and Electronic Equipment (WEEE).
This product shall not be dispose in to the domestic waste as it is made of different materials
that have to be recycled at the appropriate facilities.
Inquire through the municipal authority regarding the location of the ecological platforms to
receive the product for disposal and its subsequent correct recycling.
Furthermore, upon purchase of an equivalent appliance, the distributor is obliged to collect the
product for disposal free of charge.
The product is not potentially dangerous for human health and the environment, but if abandoned
in the environment can have negative impact on the environment.
Read carefully the instructions before using the product for the first time.
It is recommended that you do not use the product for any purpose rather than those for which
it was intended, there being a danger of electric shock if used improperly.
The crossed-out wheeled dustbin symbol, on the label on the product, indicates the
compliance of this product with the regulations regarding Waste Electrical and Electronic
Equipment.
Abandonment in the environment or illegal disposal of the product is punishable by law.