Wired controller 

GIA

-XK46

4

Wired Controller XK46

1

1  SAFETY  NOTICES  (PLEASE  BE  SURE  TO 

ABIDE )

 

Warning: If not abide strictly, it may cause severe damage to the unit or 
the people. 
Note: If not abide strictly, it may cause slight or medium damage to the unit 
or the people. 
This sign indicates that the operation must be prohibited. Improper 
operation may cause severe damage or death to people. 
This sign indicates that the items must be observed. Improper operation 
may cause damage to people or property. 

WARNING! 

This product can’t be installed at corrosi

ve , inflammable or explosive 

environment or the place with special requirements, such as kitchen. Otherwise, it 
will affect the normal operation or shorten the service life of the unit, or even cause 
fire hazard or serious injury. As for above special places, please adopt special air 
conditioner with anti-corrosive or anti-explosion function .

Содержание GIATSU GIA-XK46

Страница 1: ...GIA XK46 OWNER S INSTALLATION MANUAL WIRED CONTROLLER Thanks for choossing our product Please read carefully this manual before using the product ENGLSIH...

Страница 2: ...ect to actual operation 3 In order to make the product better we will continuously conduct improvement and innovation We have the right to make necessary revision to the product from time to time due...

Страница 3: ...1 ON OFF 28 6 2 MODE SETTING 28 6 3 TEMPERATURE SETTING 29 6 4 FAN SETTING 30 6 5 TIMER SETTING 31 6 6 SWING SETTING 38 6 7 QUIET SETTING 39 6 8 SLEEP SETTING 42 6 9 AIR SETTING 43 6 10 LIGHT ON OFF S...

Страница 4: ...n may cause severe damage or death to people This sign indicates that the items must be observed Improper operation may cause damage to people or property WARNING This product can t be installed at co...

Страница 5: ...ng on that of master indoor unit Master indoor unit can switch to any modes while slave unit can t switch to the mode that is conflicting with master indoor unit When master indoor unit changes mode w...

Страница 6: ...Wired controller GIA XK46 6 Wired Controller XK46 3 3 DISPLAY Fig 3 1 Appearance of wired controller 3 1 LCD OF WIRED CONTROLLER Fig 3 2 LCD graphics of wired controller...

Страница 7: ...then the temperature zone will display FAP 6 Cooling mode 7 Dry mode 8 Fan mode Heating mode Wired Controller XK46 5 9 Instructions 10 When inquiring or setting project number of indoor unit it displ...

Страница 8: ...ave status of indoor unit 32 It indicates the current wired controller is the slave wired controller address of wired controller is 02 33 Memory status The indoor unit resumes the original setting sta...

Страница 9: ...Switch among auto low speed low medium speed medium speed medium high speed high speed and turbo status 6 MODE Switch Auto Cooling Dry Fan Heating Floor Heating 3D Heating and Space Heating modes for...

Страница 10: ...9X25 MA Soleplate of wired controller Q ty 1 3 2 8 8 TIMER Timer setting 9 SWING Set up and down swing status 10 ON OFF Indoor unit On Off 2 5 Simultaneously press and for 5s to enter or cancel the C...

Страница 11: ...ler GIA XK46 11 Wired Controller XK46 Edition Two Fig 5 1 2 Parts of wired controller No 1 2 3 4 Name Panel of wired controller Self tapping Screw ST3 9X25 MA Screw M4 25 Soleplate of wired controller...

Страница 12: ...e sheathed cord 60227 IEC 52 60227 IEC 53 L 250m L 820 1 5feet 2 0 75 mm 2 2 1 25 mm 2 2 AWG1 8 2 AWG 16 IEC 60227 5 2 007 1 Total length of communication line can t exceed 250m 820 1 5feet 2 The cord...

Страница 13: ...s 3 Prohibit installing the wired controller at the place near high temperature objects or water splashing places 4 Prohibit installing the wired controller at the place where faces forward to the win...

Страница 14: ...troller can connect to any one indoor unit but the connected indoor unit must be the same series indoor unit The total quantity of indoor unit controlled by wired controller can t exceed 16 sets and t...

Страница 15: ...its Please refer to 5 2 3 Parameters Setting 4 When one or two wired controller s control s multiple indoor units at the same time the controlled indoor unit s setting should be the same 5 Wiring of w...

Страница 16: ...roller GIA XK46 16 Wired Controller XK46 17 5 1 4 Installation There re two editions of wired controller The Installation way is different Installation way one Fig 5 7 Installation diagram for wired c...

Страница 17: ...pair to H1 and H2 wiring column and then fix the screws 5 Set two core into the groove at left side of wiring column and then bundle panel and Soleplate of wired controller together Note If the wire s...

Страница 18: ...Master Indoor Unit Under Off status long press MODE button for 5s to set the corresponding indoor unit of wired controller as master indoor unit MASTER icon will be light after finishing setting Note...

Страница 19: ...ith an interval of 3 seconds if there are several malfunctions in one indoor unit Timer zone displays present indoor unit project number C5 malfunction of project number conflict Note 1 If master indo...

Страница 20: ...project number Timer zone displays current priority operation setting value of indoor unit C07 View indoor ambient temperature Operation method Enter viewing press MODE button in C07 status to enter t...

Страница 21: ...olled by the wired controller C12 View outdoor ambient temperature Timer zone displays outdoor ambient temperature C17 View indoor relative humidity 20 90 relative humidity20 90 Operation method Enter...

Страница 22: ...After turning on the one button viewing function each wired controller of the entire system will display the project number of its controlling indoor unit on its timer zone The timer zone will displa...

Страница 23: ...door Unit Note Under parameter viewing status FAN TIMER SLEEP and SWING buttons are invalid Press ON OFF button to go back to the home page while not to turn on off the unit Under parameter viewing st...

Страница 24: ...s master indoor unit MASTER icon will be bright after finishing setting P11 Set infrared receiver of wired controller 00 forbidden 01 activated 01 It can be set only through master wired controller Wh...

Страница 25: ...There are two kinds of static pressure level 5 levels 03 04 05 06 07 9 levels 01 02 03 04 05 06 07 08 09 Wired controller can be adapted to the different types of indoor units that it possesses 1 9 l...

Страница 26: ...When the temperature unit is F cooling setting temperature minus heating setting temperature 2 F P38 Heating setting temperature under auto mode 16 C 29 C 61 F 84 F 20 C 68 F P43 Set priority operatio...

Страница 27: ...Fresh Air Indoor Unit P54 Union setting of Fresh Air Indoor Unit 00 without union control 01 with union control 00 After union function is set Fresh Air Indoor Unit will be turned on off following th...

Страница 28: ...turn off the unit The interfaces of On Off status are shown in fig 6 1 6 4 Fig 6 1 Interface of On status in Celsius Fig 6 2 Interface of Off status in Celsius Wired Controller XK46 32 Fig 6 3 Interfa...

Страница 29: ...ases or decreases set temperature by 1 C or 1 F holding or button increases or decreases set temperature by 1 C or 1 F every 0 3s In Cooling Fan Heating Floor Heating 3D Heating or Space Heating mode...

Страница 30: ...h Air Indoor Unit fresh air indoor unit code FAP will be displayed as shown below Setting temperature won t be displayed and can t be adjusted via or button The air outlet temperature in cooling or he...

Страница 31: ...cancel Turbo function Press FAN button to cancel turbo function and start auto speed Note In Dry mode fan speed is low and can t be adjusted When the wired controller is connected with a Fresh Air Ind...

Страница 32: ...and HOUR icon is blinking Press or button to adjust timer time Press TIMER button to save the setting and then exit setting Cancel Timer when timer is set press TIMER button to cancel it Timer settin...

Страница 33: ...Wired controller GIA XK46 33 Wired Controller XK46 Fig 6 5 Timer Off setting in unit On status in Celsius Fig 6 6 Timer Off setting in unit On status in Fahrenheit...

Страница 34: ...it On Off at a certain time can be set through clock timer Set Timer 1 Press TIMER button to enter timer on setting and the ON icon is blinking 2 Press or button to adjust unit On time Press ENTER CAN...

Страница 35: ...Wired controller GIA XK46 35 Wired Controller XK46 40...

Страница 36: ...Wired controller GIA XK46 36 Wired Controller XK46 41 Fig 6 7 Unit On Off time setting in unit On status in Celsius...

Страница 37: ...Wired controller GIA XK46 37 Wired Controller XK46 Fig 6 8 Unit On Off time setting in unit On status in Fahrenheit...

Страница 38: ...on status press SWING button to start or stop up down swing 2 When fixed angle swing mode is set in unit on status press SWING button to adjust swing angle circularly as below 2 Left right swing funct...

Страница 39: ...Space heating mode Turn on Quiet Function press FUNCTION button to turn to Quiet function and then Quiet icon or auto quiet icon is blinking At this moment press or button to switch between quiet and...

Страница 40: ...Wired controller GIA XK46 40 Wired Controller XK46 45 Fig 6 9 Setting of Quiet function in Celsius...

Страница 41: ...ction is enabled indoor unit will operate at quiet fan speed Fan speed is lowered so as to reduce the noise of indoor fan motor When Auto Quiet function is enabled indoor unit will change fan speed au...

Страница 42: ...ep function is closed while quiet function is still activated Under Auto Fan or Floor Heating mode this Sleep function is not available 6 9 AIR SETTING Air Function Adjust the amount of indoor fresh a...

Страница 43: ...Wired controller GIA XK46 43 48 Fig 6 11 Turn on Air Function in Celsius Fig 6 11 or 6 12 Shows how to turn on Air function...

Страница 44: ...Wired controller GIA XK46 44 Wired Controller XK46 49 Fig 6 12 Turn on Air Function in Fahrenheit...

Страница 45: ...t When unit is on or off press FUNCTION button to select Light function icon will blink Press ENTER CANCEL to turn on the light Turn off the Light When light of indoor unit is on press FUNCTION button...

Страница 46: ...Dry modes and setting maximum temperature under Heating 3D Heating and Space Heating modes Thus energy saving can be realized Start up Save function for Cooling When the unit is off simultaneously pre...

Страница 47: ...Wired controller GIA XK46 47 Wired Controller XK46 53 Fig 6 14 Save Setting for Cooling in Fahrenheit...

Страница 48: ...press TIMER and buttons for 5s to enter into save setting press ENTER CANCEL button to cancel Save function of all modes Note When the Save function is turned on and then set temperature exceeds the...

Страница 49: ...CEL function to cancel this setting When Filter Clean Reminder time is up icon will light up to remind you to clean the filer Press FUNCTION button to turn to Filter Clean Reminder Function then press...

Страница 50: ...te Description on cleaning level When setting the Filter Clean Reminder Function timer zone will display 2 digits of which the former indicates the pollution degree of operating place and the latter i...

Страница 51: ...9 it means the operating time is 5000 hours Heavy Pollution The former digit shows 3 while the latter one shows 0 which indicates the accumulating operating time is 100 hours Each time the latter dig...

Страница 52: ...blink Then press ENTER CANCEL button to turn off this function 6 15 REMOTE SHIELD FUNCTION Remote Shield Function Remote monitor or central controller can disable the relevant functions of wired contr...

Страница 53: ...cover the operation as state in memory When the card is pulled off or improperly inserted icon will show neither remote control nor operation of wired controller will be effective and icon will be fli...

Страница 54: ...Protection FP Malfunction of DC motor b6 Gas liquid separator inlet temperature sensor error E3 Low Pressure Protection FU Compressor 2 Top Temperature Sensor Error b7 Gas liquid separator outlet tem...

Страница 55: ...Outlet Pipe Temperature Sensor Error JF Oil return pipe is leaking P3 Protection of Compressor Drive Board Module Reset FE Compressor 4 Current Sensor Error JL Protection of Low High pressure H0 Erro...

Страница 56: ...Temperature Sensor Error 65 L8 Power Insufficiency Protection d4 Inlet Pipe Temperature Sensor Error dn Swing Assembly Error L9 Quantity Of Group Control Indoor Units Setting Error d5 Malfunction of...

Страница 57: ...or between master control and inverter compressor drive CH Rated capacity is too high Wired Controller XK46 66 Error Code Content Error Code Content Error Code Content U5 Wrong Address of Compressor D...

Страница 58: ...it is waiting for debugging A8 Vacuum pumping Mode AJ Filter Clean Reminder A1 Check the compressor operation parameters Ab Emergency Stop AU Remote Urgent Stop A2 After sales Refrigerant Reclaim Ad O...

Страница 59: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info giatsu com www giatsu com...