GIA GIA-MCF-18M01 Скачать руководство пользователя страница 7

Unitary Duct Split Unitary Duct Split

 

  Selection of Installation Location and 

Precautions 

1Selection  of  Installation  Location  for  Air  Conditioner 
Unit 

The installation of air conditioner unit must be in accordance with national and local 

safety codes. 

Installation quality will directly affect the normal use of air conditioner unit. The user 

is  prohibited  from  installation  by  himself.  Please  contact  your  dealer  after  buying  this 

machine.  Professional  installation  workers  will  provide  installation  and  test  services 

according to installation manual. 

Do not connect to power until all installation work is completed. 

2 Selection of Installation Location 

Such a place where cool air can be distributed throughout the room. 

Such a place where is condensation water is easily drained out. 

Such a place that can handle the weight of indoor unit. 

Such a place, which has easy access for maintenance. 

Such a place where is permitting easy connection with the outdoor unit. 

Such a place where is 1m or more away from other electric appliances such as 

television, audio device, etc. 

Avoid a location where there is heat source, high humidity or inflammable gas. 

Do not use the unit in the immediate surroundings of a laundry, a bath, a shower 

or a swimming pool. 

Be sure that the installation conforms to the installation dimension diagram. 

3 Caution for installation where air conditioner trouble is 
likely to occur 

Where there is too much of oil. 

Where it is acid base area. 

Where there is irregular electrical supply. 

  Installation of Floor And Ceiling Type Indoor Unit 

1 Space dimension for installation of the unit 

Содержание GIA-MCF-18M01

Страница 1: ...OWNER S AND INSTALLATION MANUAL FLOOR AND CEILING INDOOR MULTI M01 GIA MCF 18M01 GIA MCF 24M01 ENGLSIH Thanks for choossing our product Please read carefully this manual before using the product...

Страница 2: ...unit will stop At this time change the operation mode of the indoor unit to the one that would not clash with the outdoor operating mode to make the operation normal The cooling mode is not clash wit...

Страница 3: ...is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Correct Disposal of this product This marking indicates that this product...

Страница 4: ...CE DIMENSION FOR INSTALLATION OF THE UNIT 3 2 IMPORTANT NOTICE 4 3 THERE ARE 2 STYLES OF INSTALLATION 4 4 ELECTRICAL WIRING 7 5 INSTALL THE DRAINAGE PIPE 9 6 INSTALL THE CONNECTION PIPES 10 CONSTITUTE...

Страница 5: ...cord is normal otherwise electric shock or fire may happened Do not cut off the power supply to turn off the unit when it is running otherwise life time of units may shortened Do not mangle wire or a...

Страница 6: ...eaning the conditioner otherwise electric shock or harm may be happened Chemical sprayer should be placed 1m or more away from the unit otherwise fire or explode may be caused Do not let blockage happ...

Страница 7: ...ed throughout the room Such a place where is condensation water is easily drained out Such a place that can handle the weight of indoor unit Such a place which has easy access for maintenance Such a p...

Страница 8: ...department that is not special nominated by GIATSU would not deal with on time by the inconvenience of the business contact b It should be done by professional personnel when the air conditioner unit...

Страница 9: ...the distance from the unit to the ceiling slab beforehand Refer to Fig 4 d Fix the hanger bracket to the suspension bolt Warning Make sure that extended suspension bolt from the ceiling stays inside...

Страница 10: ...ckets from the indoor unit Refer to Fig 9 Be sure to use only the specified accessories and parts for installation work When installing the indoor unit you can refer the paper pattern for installation...

Страница 11: ...ugh the piping hole of the chassis and the bottom of the appliance upward then connect the brown wire to the Terminal board 3 black wire the communication wire to the Terminal board 2 blue wire to the...

Страница 12: ...Unitary Duct Split Unitary Duct Split 8...

Страница 13: ...pe should be equal to or greater than the diameter of the connecting pipe Keep the drain pipe short and incline downwards at a gradient of at least 1 100 to prevent air pockets Refer to Fig 10 Use the...

Страница 14: ...elative leading pipe tie the nut on tie in of the connect pipe tightly Caution Be careful in bending the connection pipes or you will damage the pipes If the tightening torque is too great in tighteni...

Страница 15: ...y Duct Split 11 Constitutes and Names of Every Part of Floor And Ceiling Type Indoor Unit Suitable model GIA MCF 12M01 GIA MCF 18M01 GIA MCF 24M01 Note The appearances will be same by the different mo...

Страница 16: ...o not make the air conditioner wet or electric shock may be lead Ensure that the air conditioner will not be cleaned by water rinsing under any circumstance Volatility liquid like thinner or gasoline...

Страница 17: ...filter had been install well by professional In order to start up the air conditioner smoothly after long time s turned off turn on the main power supply 8 hours before turning on the air conditioner...

Страница 18: ...Unitary Duct Split Unitary Duct Split 14 Operating Instructions...

Страница 19: ...Unitary Duct Split Unitary Duct Split 15...

Страница 20: ...d Is the circuit protector started aside Is the voltage too high or too low If TIMER had been set in wireless remote controller Notice all above should be operated by professional The cooling heating...

Страница 21: ...fuse or protector cut frequently Substance or water pulled in the unit involuntary Water leakage in room Over heat of power cord Odor is given out when running 2 After sales Service When having qualit...

Страница 22: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info giatsu com www giatsu com...

Отзывы: