![Ghibli AS40 KS Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/ghibli/as40-ks/as40-ks_use-and-maintenance-manual_2220285011.webp)
ENGLISH 11
8.
PUTTING INTO SERVICE
:
-‐
Make sure that the power plug is correctly inserted in the power socket.
-‐
Make sure that the flexible hose is regularly inserted and blocked in the appropriate suctionvent.
-‐
Make sure that the power cord and the possible used extension are intact, in aperfect state of
conservation.
-‐
Hold the flexible hose extremity with the chosen vacuum accessory.
-‐
Press “I” to start vacuuming.
-‐
Press “0” to stop vacuuming.
-‐
When the pressure gauge indicator is in the red zone, check the vacuum filters and tube.
! ATTENTION, DANGER
In the case of M and H Class vacuums, only use hoses with a diameter indicated in the “Technical Data”
chart.
! ATTENTION, DANGER
During functioning, always check that the manometer hand remains in the green sector. If the hand
moves in the red zone it means that it’s necessary to clean or replace the filters.
9.
SHAKING THE PRIMARY FILTER
! ATTENTION, DANGER
Turn off the machine before shaking the filter. Do not shake the filter when the machine is on.
Use the lever “C” to shake the filterFigure 2 by moving it left and right a few times.
Wait before restarting in order to allow dust todeposit. If the hand remains in the red zone even after
shaking the filter, replace the filtering systems.
DUSTS CONTAINER EMPTYING
! ATTENTION, DANGER
Before performing these operations, turn off the machine and remove the plug from the power socket.
! ATTENTION, DANGER
These operations can be performed, in accordance with the current laws, only by specialized and trained
personnel, while wearing the necessary safetyclothing.
In any case, always refer to the current national standards and laws.
-‐
Release the dusts container “K” Figure 1, remove and empty it.
-‐
Check the sealing gasket integrity and correct positioning
-‐
Reposition and hang it backup.