www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
ITALIANO
- 9
Water level sensors cleaning
- Release the levers (1 Fig. A) and remove
the entire head unit (2 Fig. B).
- Turn the entire head unit upside down.
- Clean the water level sensors (41 Fig. S)
and check the state of wear.
- Reassemble all parts in reverse order of
disassembly.
Vacuum motor filter checking and
clean
- Release the two catches (42 Fig. T) and
remove the cover (43 Fig. T).
- Remove the sponge filter (44 Fig. T)
- Clean the sponge with a jet of air (45 Fig.
T).
The sponge filter can be washed in warm
water and must only be replaced once
they are completely dry; if too dirty, re-
place it with new one.
- Reassemble everything in reverse order
of disassembly.
SPARE PARTS
Code
Description
M Class
H Class
2512772
Main panel filter Class M
■
■
6895010
Cartridge filter Class H
■
6010530
Flexible hose D.33 Mt.4 AS
■
■
6010531
Flexible hose D.29 Mt.4 AS
■
■
6010533
Flexible hose D.33 Mt.4 STD
■
■
6010536
Flexible hose D.38 Mt.4 STD
■
■
Manuale 8050902 TOOL PRO WDA 40 P_1ed_06-2021.indd 9
Manuale 8050902 TOOL PRO WDA 40 P_1ed_06-2021.indd 9
29/06/2021 10:08:05
29/06/2021 10:08:05