www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
ITALIANO
- 5
PREPARING
THE APPLIANCE
Vacuum cleaner
DANGER:
For Class M and H vacuum clean-
ers, use only hoses with a diam-
eter indicated in the table “Tech-
nical Data / Class M and Class
H suction tube diameters”. Also
read the instructions in the para-
graph “Suction tube diameter
switch”.
For appliances equipped with suitable acces-
sories:
- Release the levers (1 Fig. A) and remove
the entire head unit (2 Fig. B).
- Check that the fleece filter bag (4 Fig. C)
is inserted in the waste container (3 Fig.
C).
- If the fleece filter bag is not present, insert
it as follows:
Slot the fleece filter bag onto the nozzle
(5 Fig. C) over the neck (6 Fig. C).
Arrange the fleece filter bag carefully in-
side the waste container (3 Fig. B).
- Reassemble the entire head unit (2 Fig.
B) and secure it with the levers (1 Fig. A).
- Insert the sleeve (7 Fig. D) of the suc-
tion hose into the nozzle (8 Fig. D) on the
waste container.
To release the sleeve (7 Fig. D), turn it
slightly and pull it outwards.
NOTE:
When the nozzle (8 Fig. D) is not in use,
close it with the cap (9 Fig. D) provided.
- Screw on the ergonomic handle (11 Fig.
E) to connect it to the flexible tube (10
Fig. E).
- Connect the extension (12 Fig. F) to the
ergonomic handle (11 Fig. F).
- Join the two rigid extensions (12-13 Fig.
G).
- Attach the chosen accessory to the rigid
extension (13 Fig. H) (suction nozzle,
brush attachment, crevice tool, etc., Fig.
H).
NOTE:
The suction force can be adjusted on the
grip, by turning the handle (14 Fig. I).
Rotate the handgrip over the little window (15
Fig. I) to decrease the suction.
NOTE:
The reduction sleeve can be installed on the
flexible tube (10 Fig. E).
Tools connection
Power tool connection
- Lift the cover (16 Fig. J) and connect the
power tool plug to the outlet (17 Fig. J)
present on the head of the vacuum clean-
er (maximum power allowed 2400 W).
Pneumatic tool connection (optional)
For appliances fitted with relative attach-
ments:
- Connect the hose (18 Fig. J) of the pneu-
matic tool to the relative fitting (19 Fig. J)
present on the head of the vacuum clean-
er.
- Connect the pneumatic power supply line
(20 Fig. J) to the fitting (21 Fig. J) present
on the head of the vacuum cleaner (maxi-
mum pressure allowed 10 bar).
Liquid suction
WARNING:
Risk of electric shock!
In the event of foam or liquid leakage,
switch off the apparatus immediately.
Empty the recovery tank and clean the
filters as described in the relevant para-
graphs.
Manuale 8050902 TOOL PRO WDA 40 P_1ed_06-2021.indd 5
Manuale 8050902 TOOL PRO WDA 40 P_1ed_06-2021.indd 5
29/06/2021 10:08:03
29/06/2021 10:08:03