GGM gastro KUJ Series Скачать руководство пользователя страница 2

 

TABLES

2

OPERATING MANUAL

betriebshandbuch

TABLE OF CONTENTS

1. Purpose 

 

 

 

 

 

3

2. General Information 

 

 

 

 

3

3. Technical description 

 

 

 

 

3

3.1. Technical data 

 

 

 

 

3

3.2. Standard version   

 

 

 

4

3.3. Optional accessories 

 

 

 

4

3.4. Documents 

 

 

 

 

4

4. Operation

   

 

 

 

 

4

4.1. Cooling system 

 

 

 

 

4

4.1.1. Compressor   

 

 

 

4

4.2. Wiring system and power supply   

 

4

4.3. Installation and usage 

 

 

 

5

4.4. Transport   

 

 

 

 

5

  5. Maintenance 

 

 

 

 

6

  6. Safety considerations and workplace hygiene 

 

6

TABLES AND DIAGRAMS

Table 1.1  

KUJ 

 

 

 

 

 

 

3

Diagram 1.  

Control Panel   

 

 

 

 

5

Diagram 2.  

Electrical Circuit Schematic 

 

 

 

6

The warranty does not cover damage to glass and elements which naturally get used up: fluorescent lamps, starters, etc…

The manufacturer guarantees proper functioning of the device in Class III climate conditions, that is an ambient temperature 

not exc250 C and relative humidity up to 60%. Frosting or misting of windows is a natural process resulting from 

temperature differences when relative humidity exceeds 60%. Calling a technician in such a case would be of no use.

It is very important that this device operate on a level surface. Operating this device on a slanted surface is not permitted - this 

might make condensation difficult and lead to a malfunction.

The device’s compressor is designed to operate with a voltage of no less than 210 V and no more than 240 V. Using this device 

beyond these power parameters may lead to irreversible damage to the device.

If the condenser needs to be cleaned, and it should be at least once every two months, use a soft brush and brush along the 

ribs in order to remove dust and other residue.

The manufacturer does not bear responsibility for damage to the device resulting from an uncleaned condenser.

If the permanently-fixed power cord becomes damaged, then it must be replaced through the manufacturer, at a specialized 

repair facility, or by a qualified technician in order to prevent injury.

Do not block the condenser’s fan vents.

Protect the cooling circuitry from any damage.

Do not use any electrical devices inside the cooling chamber.

The confectionery display cabinet should be set up so that the power plug is easily accessible.

CAUTION

The device must be carefully positioned on a level surface before it is turned on.

Содержание KUJ Series

Страница 1: ...e Genehmigung von GGMgastro ist untersagt und bedeutet die Verletzung der Urheberrechte GGMgastro international Bakir Inan GbR OVERVIEW 1 OPERATING MANUAL betriebshandbuch pastry counter K u c h e n t...

Страница 2: ...is very important that this device operate on a level surface Operating this device on a slanted surface is not permitted this might make condensation difficult and lead to a malfunction The device s...

Страница 3: ...nized sheet or possibly stainless steel filled with polyurethane isothermal boiling The frame of the counter is made of zinc coated sheet powder painted and filled with polyurethane foam as thermal in...

Страница 4: ...lay thermal relay protecting the motor from unintended overload In case of an unusually loud noise of the compressor or if its start up is difficult turn of the system and check the condenser when dir...

Страница 5: ...care that the load is stacked not higher than 20 cm that products are distributed equally keeping between product items gaps to allow cooling air to circulate adequately that inlet gaps for cold air a...

Страница 6: ...to the clamps install the housing over the lamp assembly and connect the cabinet to a power source In the event that the light bulb in the display illumination assembly becomes damaged or wears out th...

Страница 7: ...inal Support fan Compressor units 1 2 3 4 5 6 7 8 9 Color codes n blue b brown t z green yellow cz black for counters with integral compressor Diagram 2 Electrical Circuit Schematic TYPE KUJ Hermetic...