GfS – Gesellschaft für Sicherheitstechnik mbH
· Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · [email protected] · www.gfs-online.com
25
GfS
Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
Cable with 12 wires
LIYY 6 x 0,14
Art.-No. 770 719
3.2.1 Wiring diagram for mains supply
GfS e-Bar® 700 73x
without reed-contact
put jumper on 1-2
T
Cable with 12 wires
Art.-No. 770719
Important:
All input contacts are 0V shortcut to ground
TK
Connecting terminal GfS e-Bar®
A
Remove connector (A) Insert
connector (B) of connecting
cable Art. No. 770719
C
Connection internal emergency
exit switch for electrically
locked emergency exits
(only GfS e-Bar
®
700 74x)
B
black
Mains supply GND
GND
–
2
green
Release command for FWS 02
(permanent open/single release)
+ 5 Volt Out
4
blue
Mainalarm
Pre-alarm
9
white
0 Volt
GND
1
violett
Electric pulse for single release or permanent signal
for permanent opening (2-7) – not
avilable when battery operated
0 Volt
GND
7
bed/blue
11
red
Mains supply (plus terminal) 10 – 30 V/DC
10–30 V/DC
+
6
brown
Checkback signal from FWS 02
(FWS 02 circuit is closed, magnet is energized)
+ 5 Volt In
5
pink
10
yellow
Mains supply GND
0 Volt
GND
3
grey
NC
NO
NO
C
C
Floating contact
see page 22
30 V/850 mA
8
grey/pink
12
2
1
2
Timer
Acces Control
System
Push buttom
switch
Door reed-contact
(automatic activation, intrusion alarm)
Floating contact
see page 22
30 V/850 mA
NOTAUSGANG ALARMG