GfS – Gesellschaft für Sicherheitstechnik mbH
· Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · [email protected] · www.gfs-online.com
19
GfS
Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.7.0 Assembly of GfS e-Bar®
Clamping bolts
3
Soft counter pressure
4
Lever arm
1
Lever arm
1
Cylinder head screw M5 x 20
8
Sunk screw M5 x 20
9
push-bar
hinge side
Lock side
base profile
2
7
5
7
6
Lift the lever arms 1 up to its maximum. Hold the lever arm with one hand and pull the push-bar profile 2 from the hinge side on the
clamping bolt 3 until the push-bar profile is engaged. Lift the lever arm with one hand, give some counter pressure on the push-bar
profile with the other hand in order to avoid that the push-bar snaps-out again.
Important: The push-bar profile must smoothely but noticably snap-in. Do not force the push-bar profile.
In case of doubt try again.
Put the protective shield 10 on the support bracket.
Insert the cover hood 7 in the bajonette joint and push it to the dead stop. Fix the cover hood with cylinder head screw M5x20 8 .
a) Mechtronic versions 7 : turn the key anti-clockwise. A noticable click indicates that the cover hood is locked.
b) Mechanic versions: Fix cover hoods with M5x8 cylinder head screws (like lock side).