GfS – Gesellschaft für Sicherheitstechnik mbH
· Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · [email protected] · www.gfs-online.com
15
GfS
Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.5.1
Mounting on wooden doors
(Metal cover sheet 770.013 for wooden doors are not included in shipment)
X
Image A
BA
19 Ø 18
38
43/50
21.5/25
Sunk-wood screw
Ø 5 x 25
Cylinder head screw
wood screw ø 5 x 25
Hinge side
Lockside
Standard flat steel base plate
Cover plate
lock side
Cover plate hinge side
Thickness depending on escutcheon 3 mm, 4 mm, 6 mm)
Counter sunk screw M4x8
(respect max. length of screw)
Shoulder bolt M4 x 4
Attention:
When installing pay attention to the orientation
of the socket. Cam has to show downwards
Detail X
max. 10
13
Image B
Attention:
Cover clip of the standard flat steel base plate
has to be mounted before the cover hood is mounted.