28
PeakStore5 Manual Version 3.0
Picture 25: Calculation of balancing masses
After the masses are applied, a validation measurement is required. The determined quality
level will be shown in the window afterwards. If the required quality level was not reached, a
further validation measurement can be added to the balancing process. The additionally cal-
culated masses must be added to the existing masses from the last validation measurement.
This step can be repeated up to 5 times.
6.3.5. Finalization
If the target quality level is within the desired range, the balancing process can be finished after
the validation measurement. The protocol of the balancing process will directly be shown in an
internal pdf viewer (see Picture 26). The measurement data and protocol are also available in
the data management section afterwards.
Picture 26: Balancing report