Error messages
Operating Instructions MSA 2 MULTI
22
5 Error
messages
In case of anomalies or errors, the MSA 2 MULTI pops up a
specific message useful to identify the possible issue. The
related number will be even tracked within the welding protocol,
to give evidence of the accident.
The error message appears on the display with the following
format:
E-1
Vi
The table below summarizes all the messages managed by the
electro-fusion unit, with a brief explanation of the possible
causes.
ERR
DISPLAY
INDICATION
MEANING
COMMENT
E1
Vi
MAINS VOLTAGE TOO LOW
Generator voltage/freq. below the threshold
E2
Vi
MAINS VOLTAGE TOO HIGH
Generator voltage/freq. above the threshold
E3
Vi
OUTAGE DURING LAST FUSION
Power cord disconnected during last fusion
E4
FUSION INTERRUPTED WITH
STOP BUTTON
Fusion stopped by the user
E5
-
AMBIENT TEMP. TOO LOW
Temp. sensor detected a value below the
threshold
E6
AMBIENT TEMP. TOO HIGH
Temp. sensor detected a value above the
threshold
E7
i
INTERNAL TEMP. TOO LOW
EF unit cannot fuse, since it is too cold
E8
i
INTERNAL TEMP. TOO HIGH
EF needs to cool down, since it is too hot
E9
FITTING RESISTANCE TOO LOW
Fitting faulty
E10
FITTING RESISTANCE TOO HIGH
Fitting faulty
E11
Vo
FUSION VOLTAGE TOO LOW
Not enough power from mains
E12
Vo
FUSION VOLTAGE TOO HIGH
Internal circuit not calibrated or faulty
E13
FUSION CIRCUIT INTERRUPTED
Power cord or output cables detached
during welding
E14
Io
FUSION CURRENT TOO HIGH
Fitting broken or circuitry not calibrated or
faulty
E15
FITTING OUT OF RANGE
Fitting is not in the right range
E16
SYSTEM ERROR
Electronic faults
Содержание MSA 2 MULTI
Страница 2: ......
Страница 29: ...Operating Instructions MSA 2 MULTI Accident Prevention 27...
Страница 30: ...Bedienungsanleitung GF Piping Systems MSA 2 MULTI Elektroschweissger t...
Страница 32: ...Operating Instructions MSA 2 MULTI 30 8 6 Arbeitssicherheit 56 8 7 Entsorgung 56...
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......