Fundamental safety precautions

The product should be installed or incorporated in such a way that effortless access to the product is guaranteed 

during any repairs and/or maintenance, and that any removal costs do not stand out of economic proportion to 

the value of the product.

2.3  Safety-conscious working

 

à

Secure workplace against unauthorised entry.

 

à

Only use the cables prescribed in the cable plan provided. Cables must be shielded in compliance with the 

wiring diagram.

 

à

Secure loose, internal drive cables with cable ties.

 

à

Before working on the electrical system:

 

à

Disconnect the drive from the 230/115 V mains and secure it against being switched back on again. Check 

isolation from power supply.

 

à

Disconnect the control unit from the 24-V rechargeable battery.

 

à

When an Uninterruptible Power Supply (UPS) is used, the system will still be under voltage even when discon-

nected from the mains.

 

à

Always use insulated wire-end ferrules for wire cores.

 

à

Danger of injury with opened drive. Hair, clothing, cables, etc. can be drawn in by rotating parts!

 

à

Danger of injury caused by unsecured crushing, impact, drawing-in or shearing spots!

 

à

Danger of injury due to sharp edges on the drive!

 

à

Danger of injury during installation through freely moving parts!

2.4  Environmentally conscious working

 

à

When disposing of the door system, separate the different materials and have them recycled.

 

à

Do not dispose of batteries and rechargeable batteries with household waste.

2.5  Safety instructions related to transportation and storage

 

X

Do not throw, do not drop product and product components.

 

X

Avoid heavy blows.

 

à

Storage temperatures under –30 °C and above +60 °C can result in damage to the product.

 

à

Protect the product against humidity.

 

à

Dry, well ventilated, closed, weather-proof and UV-protected rooms are suitable as storage areas.

2.6  Qualification

Installation of the GEZE sliding door drive may only be carried out by experts authorised by GEZE.

Содержание EC drive H KIT VP

Страница 1: ...EC drive H KIT EN Pre installation instructions VP 190486 00...

Страница 2: ...4 2 Tools and aids 6 4 3 Torques 6 4 4 Components and assembly groups 7 4 5 Bill of material VP Kit ECdrive H 7 5 Pre installation 8 5 1 Cutting the track and cover to size 8 5 2 Preparing the track 8...

Страница 3: ...s additional Information X X Symbol for an action This means you have to do something X X If there are several actions to be taken keep to the given order 1 2 Revisions and validity Version 00 valid f...

Страница 4: ...tation proper set up and installation qualified operation and correct maintenance have taken place The relevant accident prevention regulations and other generally recognised safety related or health...

Страница 5: ...even when discon nected from the mains Always use insulated wire end ferrules for wire cores Danger of injury with opened drive Hair clothing cables etc can be drawn in by rotating parts Danger of inj...

Страница 6: ...Option Component drawing Side plate right left for ECdrive H 70517 2 0229 Option Component drawing Leaf spring for cover ECdrive H The diagrams are subject to change without notice Use only the most...

Страница 7: ...to open 4 5 Bill of material VP Kit ECdrive H 1 Side plate 2 Transformer earthing 3 Transformer 4 Transformer cable 5 Return pulley 6 Cable holder 7 Toothed belt 8 Control 9 Rechargeable battery 10 G...

Страница 8: ...Track Pos 14 in assembly group list Chapter 4 4 Cover Pos 11 in assembly group list Chapter 4 4 X X Check profiles for damage X X Cut the track and cover to the required length see machining drawings...

Страница 9: ...ntil they are in contact with the track Do not tighten the setscrews The exact position of the stop buffers 1 is speci fied during door leaf installation 5 3 1 Installing the side plates X X Screw the...

Страница 10: ...drive drawings Illustrated 1 leaf W 700 mm AL Illustrated 2 leaf W 900 mm AL Legend AL Length of drive W Opening width UM Return pulley motor UR Return pulley X X Install the components with the scre...

Страница 11: ...anger of injury due to impact and crushing When the rechargeable battery cable is plugged in the door leaves can move unexpectedly X X Make sure that the rechargeable battery cable is not plugged into...

Страница 12: ...cured in such a way that they do not become jammed when the cover is positioned and cannot come into contact with moving components X X Cut the transformer cable 1 from the trans former to the control...

Страница 13: ...the control unit through the cable holders 4 and 5 to the transformer X X Fit the transformer cable 1 to the terminal 6 of the transformer 6 1 X X Set cover on control unit and lock in place The reten...

Страница 14: ...X X The electrical system 230 115 V may only be connected and disconnected by a professional electrician X X Carry out mains connection and earth conductor test in accordance with VDE 0100 Part 610 X...

Страница 15: ...nstallation the drive unit is prepared for later installation The current drive drawing is applicable for carrying out the installation work All components must be identified and installed in accordan...

Страница 16: ...nce fr geze com www geze fr Hungary GEZE Hungary Kft E Mail office hungary geze com www geze hu Iberia GEZE Iberia S R L E Mail info es geze com www geze es India GEZE India Private Ltd E Mail office...

Отзывы: