GEZE EC drive H KIT VP Скачать руководство пользователя страница 3

ECdrive H KIT

3

Introduction

Introduction

1.1  Symbols and illustrations

Warning notices

In these instructions, warnings are used to warn against material damage and injuries.

 

X

Always read and observe these warnings.

 

X

Observe all measures marked with the warning symbol and warning word.

Warning 

symbol

Warning word Meaning

DANGER

Danger to persons. 

Non-compliance will result in death or serious injuries.

WARNING

Danger to persons. 

Non-compliance may result in death or serious injuries.

CAUTION

Danger to persons. 

Non-compliance can result in minor injuries.

More symbols and illustrations

Important information and technical notes are highlighted to explain correct operation.

Symbol

Meaning

 

means “important note”. 

Information to prevent property damage, to understand or optimise the operation sequences.

 

means “additional Information”

 

X

 

Symbol for an action: This means you have to do something.

 

X

If there are several actions to be taken, keep to the given order.

1.2  Revisions and validity

Version 00: valid for ECdrive H Kit from date of manufacture 2019.

1.3  Product liability

In compliance with the liability of the manufacturer for his products as defined in the German “Product Liability 

Act”, compliance with the information contained in this brochure (product information and intended use, misuse, 

product performance, product maintenance, obligations to provide information and instructions) must be en-

sured. Failure to comply releases the manufacturer from his statutory liability. 

1.4  Reference documents

Type

Name

Drive drawing

ECdrive H

Wiring diagram

DCU1-NT / DCU1-2M-NT

Additional wiring diagrams

DCU1-NT-OP

User manual

DCU1-NT-OP

Cable plan

Single leaf

Double leaf

Safety analysis

Automatic sliding doors

Installation instructions

ECdrive H

These documents are subject to change. Use only the most recent version.

Содержание EC drive H KIT VP

Страница 1: ...EC drive H KIT EN Pre installation instructions VP 190486 00...

Страница 2: ...4 2 Tools and aids 6 4 3 Torques 6 4 4 Components and assembly groups 7 4 5 Bill of material VP Kit ECdrive H 7 5 Pre installation 8 5 1 Cutting the track and cover to size 8 5 2 Preparing the track 8...

Страница 3: ...s additional Information X X Symbol for an action This means you have to do something X X If there are several actions to be taken keep to the given order 1 2 Revisions and validity Version 00 valid f...

Страница 4: ...tation proper set up and installation qualified operation and correct maintenance have taken place The relevant accident prevention regulations and other generally recognised safety related or health...

Страница 5: ...even when discon nected from the mains Always use insulated wire end ferrules for wire cores Danger of injury with opened drive Hair clothing cables etc can be drawn in by rotating parts Danger of inj...

Страница 6: ...Option Component drawing Side plate right left for ECdrive H 70517 2 0229 Option Component drawing Leaf spring for cover ECdrive H The diagrams are subject to change without notice Use only the most...

Страница 7: ...to open 4 5 Bill of material VP Kit ECdrive H 1 Side plate 2 Transformer earthing 3 Transformer 4 Transformer cable 5 Return pulley 6 Cable holder 7 Toothed belt 8 Control 9 Rechargeable battery 10 G...

Страница 8: ...Track Pos 14 in assembly group list Chapter 4 4 Cover Pos 11 in assembly group list Chapter 4 4 X X Check profiles for damage X X Cut the track and cover to the required length see machining drawings...

Страница 9: ...ntil they are in contact with the track Do not tighten the setscrews The exact position of the stop buffers 1 is speci fied during door leaf installation 5 3 1 Installing the side plates X X Screw the...

Страница 10: ...drive drawings Illustrated 1 leaf W 700 mm AL Illustrated 2 leaf W 900 mm AL Legend AL Length of drive W Opening width UM Return pulley motor UR Return pulley X X Install the components with the scre...

Страница 11: ...anger of injury due to impact and crushing When the rechargeable battery cable is plugged in the door leaves can move unexpectedly X X Make sure that the rechargeable battery cable is not plugged into...

Страница 12: ...cured in such a way that they do not become jammed when the cover is positioned and cannot come into contact with moving components X X Cut the transformer cable 1 from the trans former to the control...

Страница 13: ...the control unit through the cable holders 4 and 5 to the transformer X X Fit the transformer cable 1 to the terminal 6 of the transformer 6 1 X X Set cover on control unit and lock in place The reten...

Страница 14: ...X X The electrical system 230 115 V may only be connected and disconnected by a professional electrician X X Carry out mains connection and earth conductor test in accordance with VDE 0100 Part 610 X...

Страница 15: ...nstallation the drive unit is prepared for later installation The current drive drawing is applicable for carrying out the installation work All components must be identified and installed in accordan...

Страница 16: ...nce fr geze com www geze fr Hungary GEZE Hungary Kft E Mail office hungary geze com www geze hu Iberia GEZE Iberia S R L E Mail info es geze com www geze es India GEZE India Private Ltd E Mail office...

Отзывы: