E-ISM Boxer
Mounting and securing
6.2 Mounting fixed leaf guide rail
M5x12
4,5x30
Fig.: 6.2.1
X
Insert the sliding pad into the guide rail for the fixed leaf, making sure it faces the right way (
1.
).
X
Fasten guide rail for fixed leaf with 2 screws (
2.
) (tightening torque: 2 Nm).
X
Clip the end cap onto the guide rail (
3.
).
X
Thread the cable and the steel wire (ball to the moving) leaf through the chamber to the recess in the guide
rail of the moving leaf (
4.
).
X
Please make sure that the cables are retained in the upper chamber of the guide rail (
5.
).
All screwing torques are to be adjusted on site, if necessary.
6.3
Mounting moving leaf guide rail and connect 24V fixed leaf cable
M5x12
4,5x30
Red =’+’
White = ’–’.
Fig.: 6.3.1
X
Insert the sliding pad into the guide rail for the moving leaf, making sure it faces the right way (
1.
).
X
Attach the steel wire to the release lever (
2.
).
X
Fasten guide rail for moving leaf with 2 screws (
3.
) (tightening torque: 2 Nm).
X
Clip the end cap onto the guide rail (
4.
).
X
Please make sure that the cables are retained in the upper chamber of the guide rail (
5.
).
X
Connect the fixed leaf cable to the connection terminal
SF
(
6.
) (cut excess cable).
All screwing torques are to be adjusted on site, if necessary.
GB 4