background image

Geysers

TECHNICAL SPECIFICATION

Capacity

1 ltr

3 ltr

6 ltr

10 ltr

15 ltr

25 ltr

35 ltr

50 ltr

Wattage

3000 W

3000 W

2000 W

2000 W

2000 W

2000 W

2000 W

2000 W

Power Supply

230 Volts, AC, 50 Hz

Thermostat

Adjustable from 30 to 750C

Thermal Cut Out

Set to operate at 90±60C

Fusible Plug

Set to operate at 98±30C

Inner Container

Tested at 6 Bar of SS Type & 8 Bar of GL Type Geyser

Pressure

Set to operate between 6 Bar of SS Geyser & 8 Bar of GL geyser

Insulation

High Density Insulation for Energy Saving

Heating Element

Incoloy Heating Element 

TROUBLE SHOOTING

S.NO

DEFECTS

POSSIBLE ACTION

ACTION TAKEN

1

Green light not glowing

May be due to the defect of LEDs & 

thermostat check both 

Replace the defective parts

2

Only red light glows

Thermostat not working

Replace the thermostat

3

Sparking inside the water 

heater

This happen due to the loose electric 

connection at heating element

Tighten the electric connections then 

start the water heater

4

Leakage 

First check the apparatus plate at 

heating element , gasket & main 

gasket then check the water tank

If there is leakage change respective 

part

5

No hot water

If green light glows & no hot water it 

means element problem

Replace the heating element

Содержание GLASSLINE PRIME

Страница 1: ...Geyser INSTRUCTION MANUAL CUM WARRANTY CARD IS 2082...

Страница 2: ...instruction manual carefully before use This instruction manual contains information as well as recommendations on the proper use of your water heater and its maintenance This Manual also contains yo...

Страница 3: ...clean the water heater 9 Do not place the power cord near any heating devices flammable or combustible agents 10 Do not use the water heater for purposes not stipulated in this Instruction Manual 11 D...

Страница 4: ...de of a scratch free rust proof and shockproof material CRC Powder coated body made of a heavy gauge CRC sheet and stove enameled for an elegant look and long life HEATING ELEMENT ISI approved mineral...

Страница 5: ...ELS Multi Function Valve MFV NON RETURN VALVE Available in SS Model only A siphon hole in the inlet pipe is provided that acts as a non return valve INDICATING LAMPS Available in some models Two light...

Страница 6: ...mostat 5 S S Tank 6 Drain Pipe 7 Safety Valve 8 Inlet 9 Outlet 1 Power cord 2 Temperature controller handle 3 Inlet nozzle 4 Outlet nozzle A 2 4 3 1 T 01 02 03 04 05 06 07 09 08 11 12 10 1 Decorative...

Страница 7: ...erhead tank should be at least 1 0 m from the top of the water heater Use a 25 mm pipe for the cold water line with minimum bends An air vent should be provided near the overhead tank to avoid airlock...

Страница 8: ...6 After you have chosen a proper place to install the water heater drill holes in the wall dimensionally fit to anchor bolts provided with the water heater Next fix the mounting strip on the wall with...

Страница 9: ...atically replaced from the mains 2 When the water reaches the required temperature the thermostat will cut off the power supply automatically 75 Deg Cel approx 3 The thermostat setting can be changed...

Страница 10: ...ng Heating Element Incoloy Heating Element TROUBLE SHOOTING S NO DEFECTS POSSIBLE ACTION ACTION TAKEN 1 Green light not glowing May be due to the defect of LEDs thermostat check both Replace the defec...

Страница 11: ..._________________________________________________________________________________________ Customer Name Address_______________________________________________________________ _________________________...

Страница 12: ...oldenprime co in www goldenprime in Remain Prime reserves the right to amend or modify the specifications features at any time as when required without any prior notification Images displayed here may...

Отзывы: