Chorus Digital Vision - Technical System Manual
61
CONFIGURATION
Wall-mounting entryphone
(GW 18 360)
The wall-mounting entryphone is customised via 1 DIP switch (12-way) located inside the base of the entryphone. The table below shows
the functions associated with each switch, and the possible options.
ATTENTION:
before changing the position of any switch, make sure that the entryphone is not powered.
DIP SWITCHES
Switch
Function
Options
Description
1
Learning mode
OFF = normal operation
ON = learning mode
This allows you to activate the entryphone learning mode.
2
Sets the number of the
relay unit
2
3
module number
This sets the number of the relay unit commanded
with the push-buttons. The number corresponds to the
sequence in the project file, when programming with a
PC. With manual programming on the other hand, these
switches must necessarily be set at OFF - OFF.
OFF
OFF
1
OFF
ON
2
3
ON
OFF
3
ON
ON
4
4
Sets the command for the
AUX1 button
OFF = activates the electro-lock of
the secondary front door unit
ON = activates the electro-lock of
the relay unit
This determines whether the AUX1 command activates
the electro-lock of the secondary front door unit or of the
associated relay unit.
5
Sets the relay of the relay
unit associated with the
AUX2 button
5
6
relay number
This determines which relay output of the associated
relay unit is activated with the AUX2 command.
OFF
OFF
1
OFF
ON
2
6
ON
OFF
3
ON
ON
4
7
Sets the operation of the
local relay
OFF = relay activated when a call
is received
ON = relay activated with the “Door
opener” button
This determines whether the relay is activated automa-
tically when a call is received, or whether it is activated
with the "Door opener" push-button.
8
Confirmation beep when
using the buttons
OFF = deactivated
ON = activated
Activates or deactivates the "confirm" sound when using
the push-buttons.
9
Relay timing
9
10
11
sec
This determines how long - in seconds - the local relay
must remain closed.
OFF
OFF
OFF
2
OFF
OFF
ON
5
10
OFF
ON
OFF
10
OFF
ON
ON
30
ON
OFF
OFF
60
11
ON
OFF
ON
120
ON
ON
OFF
180
ON
ON
ON
300
12
Reset entryphone
OFF = normal operation
ON = entryphone reset
Restores the factory configuration of the entryphone.
1
ON
ON
2
3
4
5
6
7
8
1
2
3
4
1 2
3
4
5
6
7
8
9 10 11 12
Содержание Chorus Digital Vision
Страница 1: ...Video Entryphone Technical Manual ...
Страница 103: ......