Subject to technical and design changes without
prior notice.
(
fi g. B1
or
fi g. B2
). Guide the cable and the thread of the detector
head into the hole and secure using a washer and nut
(fi g. C)
. Guide
the connecting cable through the rubber grommet
fi g. D1
and mount
the wall connection plate according to
fi g. D
. The LBM motion
detector has a fl oating relay for switching lights or other devices.
Check maximum loads!
Connection: Examples
Fig. E1
= Externally powered doorbell
Fig. E2
= Lights with the same voltage as the LBM motion detector.
Connect the cable to the power supply line according to the circuit
diagram
(Fig. E)
and place the detector on the wall connection plate
Fig. F.
Switch the circuit protection back on.
Range test
Set the
TIME
controller to minimum, the
LUX
controller to “sun”
and the
METER
controller to maximum
(fi g. G)
. If the detector is
switched on via a separate switch, turn this on. A self-test is then
initiated lasting approx. 15 seconds. The connected device will
remain on throughout this time. When the device turns off, the range
test will begin. The device will now switch on for approx. 5 seconds
in response to any movement, regardless of the ambient lighting
level. This time period is initiated by any movement from the front.
This range test is designed to help you to determine the fi eld of
detection. The motion detector can be adjusted horizontally
(fi g. I)
and vertically
(fi g. H)
. The
METER
controller also allows you to set
the range. Once this has been adjusted successfully you will be able
to make further settings.
Operation
The motion detector operates using passive infrared technology. Via
a PIR sensor, the detector notices any heat sources moving within
its fi eld of detection and switches on automatically. Static heat
sources do not trigger it. The adjustable twilight switch lets you
choose whether you have the motion detector working day and night
or only when it is dark. The integrated timer also lets you adjust how
long the light stays on.
Safety information
To be fi tted by qualifi ed electricians only, observing all
standard national installation regulations.
No work to be carried out while live. The circuit trip switch
must therefore be switched off.
Check to make sure the connecting cable is not live!
All warranty claims will be null and void in the event of
any damage or loss caused by failure to observe these
operating instructions. We accept no liability for any consequential
losses or damage. We accept no liability for any personal injury or
material damage caused by improper use or by failure to observe
the safety advice.
In such cases all warranty claims will be null and void. For reasons
of safety and approval, no unauthorised conversion and/or
modifi cation of the appliance is allowed.
Where to install
The motion detector is at its most effective when approached
diagonally. Motion detectors should therefore always be set up so
that they are not directly approached.
Installation
The LBM motion detector can be mounted either on a wall or on a
ceiling
(fi g. A)
. Unplug one of the pre-punched holes that is most
suitable for the type of installation and the programmable range
Motion detector 12 volt LBM 120°
Troubleshooting – Practical tips
Problem Cause
Remedy
Motion detector switches
• Detection range setting
• Adjust detection area by
the light on too late
• Movement from the front
turning the sensor
Motion detector fails to
• Motion detector is mounted too low
• Mount higher
achieve maximum range
• Difference in temperature between heat source
and surroundings is not big enough
Motion detector switches
• Constant warm movement:
• Re-align detector and, if necessary,
light on constantly
The fi eld of detection encompasses areas
change its location
or when not necessary
that do not require monitoring, such as pathways,
roads, trees and refl ective water.
Unexpected change in heat sources due to a
storm, rain or fans.
Infl uence of direct/indirect sunlight
Fails to react to vehicles
• Vehicle has not warmed up
• Engine area is very well insulated
Technical data
Field of detection
120°
Time adjustment
approx. 5 sec. - 15 min., infi nitely variable
Range
approx. 1 m to approx. 10 m depending on installation height
and outside temperature
Twilight switch
approx. 5 - 1000 lux, infi nitely variable
Switching capacity
fl oating relais 10 A, 12 V to 30 V ~/
Power supply connections
12 V ~/
Protection type
IP 44
Recommended installation height
approx. 2.5 m
Dimension
approx. H 100 x W 80 x D 117 mm
Settings (fi g. G)
LUX
Twilight switch approx. 5 to 1000 lux
TIME
Time setting for the ON period approx. 5 sec. – 15 min.