background image

Technicals data

Mains connection 

230 V ~, 50 Hz

Power consumption LED  

max. 6 W

Power consumption (in standby mode) 

approx. 0.6 W

Luminous flux 

approx. 510 lm

Light colour 

approx. 4.000 K, white

Colour rendering index (Ra) 

CRI > 80

Field of detection 

120°

Range 

approx. 6 m for head-on/3 m for side

Time setting 

approx. 60 sec. + 60 sec., after last detected motione

Twilight switch 

approx. 85 to 200 lux

Protection type 

IP 44

Protection class 

I

Recommended installation height 

1.8 m

Dimensions 

W 116 x H 340 x D 155 mm

Technical and design features may be subject to change.

GB

FR

IT

PL

DE

6

7

Outdoor LED light with Dimmatic function, LBE 21648

Installation

Install the outdoor LED light with Dimmatic 

function, LBE 21648, according to 

Figs. A and B

We recommend an installation height of 1.8 m. 

Select a mounting position for the LED light. You 

can use the wall-mounted holder as a template 

to help you position the drill holes. Drill 2 holes in 

the surface on which you wish to install the LED 

light. Pierce the rubber seal in the wall-mounted 

holder with an appropriate tool and feed the 

connection cable through the seal. Connect the 

mains connection cable to the lustre terminal in the 

LED light 

(Fig. C)

, see wiring diagram 

Fig. D

. The 

LED light must be earthed! Replace the cover on 

the wall-mounted holder and tighten the screws. 

Switch the fuse back on. 

Activation/sensor settings (Fig. C)

When the LED light is activated for the first time, it 

will perform a self-test.

During this test, the LED light will operate at 

full power for around 45 sec., regardless of the 

ambient brightness level. It will then dim before 

switching to automatic mode (if the ambient 

brightness threshold is still exceeded). If the level 

of ambient brightness is too low, the LED light will 

stay on.

Once the LED light has been installed and 

activated, you can approach the device to perform 

a range test. Pay attention to the blue LED motion 

indicator when carrying out the test: it will light up 

briefly (by daylight) when detected by the motion 

detector; the LED light will not switch on. 

Recycling instructions

This device may not be disposed of with 

unsorted household waste. Owners of old 

devices are required by law to dispose of 

this device correctly. Contact your town 

council for further information.

By purchasing this item, you have chosen a 

high-quality GEV product. Please read these 

operating instructions carefully to ensure 

correct operation. Keep these instructions in a 

safe place so that you can refer back to them 

if necessary.

Operation

The outdoor LED light with motion detector and 

Dimmatic function has in-built, non-replaceable 

LED lamps.

The twilight switch turns on the LED light at around 

20% light power when twilight falls. The LED light 

switches off again at daybreak. If the integrated 

motion detector detects a moving heat source 

(people, cars, animals) within a radius of approx. 

6 m during this operation phase, it switches the 

LED light on at 100% light power for 60 seconds.  

60 seconds after the last movement is detected, 

the light power of the LED light is reduced to 20%. 

Static heat sources do not switch on the LED light. 

The LED light switches off automatically at 

daybreak.

Safety instructions

This device must be installed by a 

technician, in accordance with the 

applicable regulations. The electrical 

power supply and the circuit protection 

must be switched off during the entire installation 

process. 

Please check that the connection 

cable is disconnected! 

Under no circumstances does the warranty cover 

damage resulting from failure to observe these 

instructions. Nor do we accept liability for any 

indirect damage. 

Similarly, we can accept no liability for any material 

damage or bodily injury caused by mishandling 

or failure to observe the safety instructions. No 

warranty claim may be made in these cases. 

In addition, for safety and compliance reasons, 

you are not authorised to dismantle or alter the 

device in any way.

Mounting position 

Motion detection is maximised when moving at 

an angle to the motion detector. Therefore, the 

motion detector should always be installed in a 

position that ensures that objects/people do not 

move directly towards the device.

Troubleshooting – practical advice

Fault

Cause

Solution

The LED light is not 

working

• No power supply

• Check the connections/fuse

• Black out the sensor (e.g. using  

   an opaque material) then check  

   if the LED light switches on 

• Call the service hotline

The light flashes 

constantly

• Surrounding area is too bright

• Possible fault due to lights or  

 

   scattered  light

• Change the installation location 

• Remove any other light sources

Sensor range is too low

• Angle is too low

• Ambient light is interfering with the  

   sensor’s field of detection

• Increase the installation  

   

   height of the device or change  

   the angle of incidence to the   

   detection  area

LED light is constantly lit • Incorrect wiring

• The sensor is being constantly  

 

   triggered

• Check the wiring

• Fully disconnect the light from  

   the mains supply (for at least   

   30 sec.) then restart it

• Find another installation  

   

   location

LED light is triggered for 

no apparent reason  

• LED light is incorrectly positioned

• High wind speed

• Change the position of the LED  

   light

• If this is a temporary problem  

   due to bad weather

   conditions – switch off the LED  

   light 

Blue LED motion 

indicator does not light 

up

• No power supply

• LED motion indicator is faulty

• Check the wiring/fuse

• Call the service hotline

Содержание LBE 21648

Страница 1: ... deutschen Festnetz Mobil max 42 Ct Min International calls may vary GEV GmbH Heidehofweg 16 25499 Tangstedt Germany www gev de service gev de Hotline 49 0 180 59 58 555 www gev de M o dernste LED Tech n i k von GEV Typ LBE 021648 ...

Страница 2: ...E 3 2 3 1 6 2 2 A B 120 N L TOP N L TOP N L TOP N L TOP N L TOP TOP C ca 6 m D N L N L PE ...

Страница 3: ...ED Leuchte für etwa 45 Sek mitvollerLeuchtkraft unabhängigvonderaktuellen Umgebungshelligkeit Danach dimmt sie sich und schaltet sich schließlich in den Automatikmodus falls die Umgebungshelligkeitsschwelle noch überschritten ist Sollte die Umgebungshelligkeit bereits zu gering sein wird die LED Leuchte weiterhin leuchten Wenn die LED Leuchte installiert und in Betrieb genommen wurde können Sie fü...

Страница 4: ...lt non replaceable LED lamps The twilight switch turns on the LED light at around 20 light power when twilight falls The LED light switches off again at daybreak If the integrated motion detector detects a moving heat source people cars animals within a radius of approx 6 m during this operation phase it switches the LED light on at 100 light power for 60 seconds 60 seconds after the last movement...

Страница 5: ...omatiquement le luminaire à LED à env 20 de sa puissance au crépuscule et l éteint à nouveau au lever du jour Dès lors que le détecteur de mouvement intégré identifie une source de chaleur en mouvement personnes voitures animaux dans un rayon de 6 m pendant la phase de fonctionnement le luminaire à LED commute en puissance maximale pour une durée de 60 s 60 s après le dernier mouvement perçu le lu...

Страница 6: ... tramonto l interruttore crepuscolare accende la lampada a LED a circa il 20 della potenza della lampadina e la spegne automaticamente all alba Se durante questa fase operativa il rilevatore di movimento integrato rileva fonti di calore in movimento persone auto animali presenti in un raggio di circa 6 m la lampada a LED viene accesa al 100 della potenza della lampadina per 60 secondi Dopo 60 seco...

Страница 7: ...D wyłącza się samoczynnie Wskazówki bezpieczeństwa Montaż może być wykonywany wyłącznie przez specjalistę przy przestrzeganiu obowiązujących w danym kraju przepisów dotyczących instalacji elektrycznych Dozwolona jest wyłącznie praca przy odłączonym napięciu W tym celu należy bezwzględnie rozłączyć bezpiecznik obwodu prądowego Sprawdź czy w przewodzie podłączeniowym nie ma napięcia W przypadku szkó...

Отзывы: