61
EXIT
Exit the FRAME setting page and go back to ALARM DETECT main page.
• FRAME DISABLE
Select a frame to be cancelled and press <ENTER>. The selected frame wiII
then be removed from the monitored field.
• THRESHOLD
The threshold range is adjustable from 1-255. The smaller the value, the more
sensitive it is; i.e. 1: highest sensitivity; 255: lowest sensitivity.
• EXIT
Exit the ALARM DETECT menu and go back to the
<MAIN PAGE 3
to carry on
setup of WDR function
(see 3.3.20 - WDR FUNCTION).
3.3.20 WDR FUNCTION
The Wide Dynamic Range (WDR) function is especially effective in solving indoor
and outdoor contrast issues to enhance better image quality and video display. It
enables the dome to catch detailed data from the dark part (indoor) without any
saturation from the bright part (outdoor).
Select "ON"
to enable the WDR function
Select "OFF"
to disable the WDR function
Select "AUTO"
to enable the AUTO WDR function which switches the WDR
ON/OFF automatically with the intensity difference of the subject.
Select "RF (Ratio Fix)"
to enable fixed exposure ratio mode. This mode fixes
the shutter speed of a short exposure and configures the shutter speed of a long
exposure by setting the ratio with regards to a short exposure with the exposure
ratio parameter. Blocked-up shadow correction is not performed in this mode.
MAIN PAGE 3
IR FUNCTION
AUTO
ALARM SETTING
ENTER
ALARM DETECT
OFF
WDR FUNCTION
OFF
PRIVACY MASK
ENTER
TIME SETTING
ENTER
SCHEDULE ENTER
EXIT OSD
YES