3. Installation of a GeViScope system
3.1 Preconditions
Before starting with the task of connecting and adjusting your system, you should know or
familiarize yourself with the following aspects concerning the hardware and use of your
system:
•
Number and
of recording cameras
•
Number and
of input contacts for event recording
•
If ATMs and card readers are connected: log and serial parameters
•
The storage capacity necessary for picture data (additionally allow 15 % of the calculated
image storage capacity for managing the pictures)
•
Recording matrix (number of pictures per unit of time) of the corresponding cameras for
permanent and/or event recording
You should be familiar with MS Windows and should be able to install hardware and
software.
Additional points you should be familiar with for network applications:
•
Network topology and technology as well as responsibilities relating to your system
•
Names or IP addresses of computers and/or basic units to be set up.
PC mouse, keyboard and monitor for the GeViScope basic unit
You should use the following devices for setting and operation in connection with the
GeViScope standard unit:
>
S-VGA monitor with a minimum resolution of 1024 x 768 Pixels, 17 inch
recommended
>
USB or
PS/2 keyboard and mouse
3.1.1 Preconditions for network integration
You must establish the following conditions before you integrate your GeViScope
system in an existing computer network:
An operational network with TCP/IP protocol is available (100 MBit Ethernet or TokenRing).
The integration capabilities of GeViScope must first be established and verified for all
other es of network.
A network administrator must be present during initial operation so that he can intervene
immediately in the event of problems with the network.
The network administrator must make available a free IP address, with subnet mask and
standard gateway if necessary, for each GeViScope standard unit, each setting and
picture playback PC. A free IP address is additionally necessary per network segment. This
additional IP address is necessary for test set-ups during the start-up procedure and must
remain available on conclusion of the work.
With the aid of the Ping help program it must be possible to verify functional communication
between the es of installation planned for the GeViScope basic units, setting and
picture playback PCs! You can also use Ping to verify functional name resolution.
type
type
7