Fault indications and troubleshooting
8
Service instructions
5015108-00
Edition 0403
Fault code Fault
Comment
F21
Booster tank slow to fill
If filling (-B11) takes longer than 10 minutes, a fault code is generated.
Possible action:
a. Check that the shutoff valves are open and that water is reaching the machine.
b. Check that the solenoid valves open and that their filters are not clogged.
F23
High conductivity
The conductivity (-U01) is higher than the set value after the third repeat rinse.
Possible action:
a. Check that the correct type of water is connected.
F24
Low pressure in dryer
The differential pressure (-B03) is <150 Pa .
Possible action:
a. Check whether the fan, hoses or filter(s) are faulty.
b. When changing a filter, check that the new filter is correctly installed.
F25
High pressure in dryer
The differential pressure (-B03) is > 750 Pa .
Possible action:
a. Check whether the filter is clogged.
F26
Low pressure from circulation pump
The pressure (-B04) is <30 kPa.
Possible action:
a. Check the docking between machine and wash rack.
b. Check that the pump impeller rotates easily.
c. Check the direction of rotation (see installation instructions).
d. Check that the detergent is not foaming.
F27
High pressure from circulation pump
The pressure (-B04) is > 130 kPa.
Possible action:
a. Check that no nozzles in the washing arms are blocked.
F28
Low temperature in dryer
The temperature (-B05) has not risen to 20 degrees C below the set value after
two minutes.
Possible action:
a. Check that there is power on all phases up to the element.
F29
Faulty temperature sensor in booster tank. The temperature (-B06) is <0 °C or >130 °C.
Possible action:
a. Check the temperature sensor (for open-circuit or short-circuit)
F30
Faulty temperature sensor in washing chamber The temperature (-B07) is <0 °C or >130 °C.
Possible action:
a. Check the temperature sensor (for open-circuit or short-circuit)
Содержание 8666
Страница 1: ...SERVICE INSTRUCTIONS Washer disinfector Getinge 8666 8668 Mfg no SEV0320078 5015108 00 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...Safetyregulations 2 Serviceinstructions 5015108 00 Edition 0403 ...
Страница 8: ......
Страница 10: ...Technicaldata 2 Serviceinstructions 5015108 00 Edition 0403 ...
Страница 12: ...Technicaldata 4 Serviceinstructions 5015108 00 Edition 0403 Alternativeconnectionarrangements ...
Страница 14: ......
Страница 24: ......
Страница 26: ......
Страница 33: ......
Страница 37: ......
Страница 39: ......
Страница 47: ......
Страница 49: ...Repairandadjustment 2 Serviceinstructions 5015108 00 Edition 0403 ...
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ......
Страница 99: ......
Страница 100: ......
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 105: ......
Страница 106: ......
Страница 107: ......
Страница 108: ......
Страница 109: ......
Страница 110: ......
Страница 111: ......
Страница 112: ......
Страница 113: ......
Страница 114: ......
Страница 115: ......
Страница 116: ......
Страница 117: ......
Страница 118: ......
Страница 119: ......
Страница 120: ......
Страница 121: ......
Страница 122: ......
Страница 123: ......
Страница 124: ......
Страница 125: ......
Страница 126: ......
Страница 127: ......
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ...This product is manufactured by GETINGE DISINFECTION AB Ljungadalsgatan 11 Box 1505 351 15 Växjö Sweden ...