Meaning of Display Symbols and Audible Notifications 

36 

PhysioMem

®

 PM 100 2G 

77811011 

Condition 

Symbol 

Transmission in progress 
(25, 50, 75, 100 %) 
continuous 
 
 

 

Recording disturbed and deleted automatically. 
No data transmitted. 
 
 
 

 

 

 

Condition 

Capacity 

Symbol 

Charging of the 
battery required 

0 to 10 % 

 

Capacity display 

20, 40, 60, 80, 100 % 

 

 

Charging 

Sequence in 20 % steps Ca-
pacity charged is shown as 
solid block. 

 

  continuous 

Charging of the 
battery required 

Charging capacity is not 
sufficient for sending an 
ECG. A recording can be 
performed. 

 

 
 

 

Содержание PhysioMem PM 100 2G

Страница 1: ...Cardiac Diagnostics Vital Signs Monitoring Telemonitoring Operating Manual PhysioMem PM 100 2G Tele ECG Event Recorder...

Страница 2: ......

Страница 3: ...ance 15 3 5 Cleaning the Device and Accessories 16 3 6 Disposing of the Device Batteries and Accessories 17 3 7 Established Medical Practices 18 3 8 Manufacturer Responsibility 18 4 Control Elements P...

Страница 4: ...according to IEC 60601 1 2 43 10 9 1 Guidance and manufacturer s declaration electromagnetic emissions 43 10 9 2 Guidance and manufacturer s declaration electromagnetic immunity line bound disturbance...

Страница 5: ...cles like trains and cars Airplanes are excluded as long as the use of cellular radio equipment is not allowed during flight The device is battery driven and utilizes a FLASH memory to store ECG data...

Страница 6: ...short ECG strips and transfers them to a central receiving system The transmission takes place wirelessly via the integrated GSM module The device is not intended for recording and transferring of re...

Страница 7: ...ction with the re corder 2 1 Regulatory Compliance The CE Mark and Notified Body Registration Number signifies the device including accessories meets all essential requirements of the Medical Device D...

Страница 8: ...abeling 8 PhysioMem PM 100 2G 77811011 2 2 Product and Package Information The symbols and content of the device labels is described below Fig 1 Device label PhysioMem PM 100 Fig 2 Device label Wirele...

Страница 9: ...defibrillation IP64 The ingress protection classification of the PhysioMem is IP64 whereby 6 dustproof and 4 protected against splashing water IP 21 The ingress protection classification of the charg...

Страница 10: ...tic radiation FCC ID 2AOPN PM100 Federal Communications Commission Identifica tion 2 3 Additional Symbols on the Packaging Label The symbols and content of the packaging label is described below The u...

Страница 11: ...s defined as a source of potential injury to a person WARNING indicates a potential hazard or unsafe practice which if not avoided could result in death or serious injury CAUTION indicates a potential...

Страница 12: ...CK LANYARD Neck lanyards present a possible strangulation risk Do not wear the device with the neck lanyard around your neck while you are sleeping WARNING RISK OF CONTAMINATION OR INFECTION Recorder...

Страница 13: ...to be in such an environment possibly for job related reasons WARNING MALFUNCTION OF PACEMAKERS AND ICD The device has an inte grated mobile transmission module Active mobile transmission de vices in...

Страница 14: ...se mobile phones or other electrical equipment such as computers or electrical tools close to the device That may cause interference CAUTION Switch off the device in locations where the use of mobile...

Страница 15: ...ECG data keep the device pro tected against unauthorized access by third persons CAUTION When wearing the device ensure that the electrodes do not contact other conductive parts including earth 3 4 Sa...

Страница 16: ...n Also switch off the device before shipping to prevent inad vertent data transmission CAUTION Repairs must be carried out only by persons authorized by GETEMED If you find or even suspect a malfuncti...

Страница 17: ...disinfection agents only in accordance with the manufacturer s instructions Make sure to use the correct dilution factor GETEMED recommends disinfecting the device with a 70 alcohol solution CAUTION...

Страница 18: ...ructions listed in this manual IN NO WAY supersede established medical practices concerning patient care Under all circumstances proceed according to established medical practices 3 8 Manufacturer Res...

Страница 19: ...nts Putting into Operation 4 1 Control Elements 1 2 Fig 3 Button and display 1 Button for switching on and off and for starting a recording 2 Display for the indication of operating modes and error co...

Страница 20: ...n 0 C the device should not be charged The device has a built in rechargeable battery which is charged by inductive coupling with the Wireless Charging Transmitter Pad charging pad Before first use of...

Страница 21: ...has been switched on the display of the device and an LED on the charging pad show that the battery is being charged see the table in section 7 1 page 35 The green LED is lit as soon as the charging p...

Страница 22: ...ed on while it is on the charging pad If the battery of the device has been fully charged the orange LED goes out and only the green LED is lit Fig 8 Fig 8 Charging process completed NOTE If the orang...

Страница 23: ...ing the battery after complete discharge takes approx 3 hours A fully charged battery lasts approx 5 days in typical use 3 ECG recordings per day Press the button 1 to switch on the device The progres...

Страница 24: ...g into Operation 24 PhysioMem PM 100 2G 77811011 NOTE If the battery power is too low for using the device this is indicated in the display Fig 11 when a recording is started Fig 11 Indication of insu...

Страница 25: ...is mid sternum Fig 12 Make sure that all four electrodes have skin contact and that there are no pieces of clothing or other items between electrode and skin The manufacturer recommends always wearing...

Страница 26: ...g duration is 40 seconds During this time breathe steadily refrain from jerky body movements and avoid changing the device s position on the chest During recording every heart beat R R is accompanied...

Страница 27: ...th strong chest hair shortly move the device back and forth so that no hair obstructs the contact between electrodes and skin NOTE Skin contact of the electrodes can be impaired when the skin is too d...

Страница 28: ...ys successful After recording the device automatically switches to sending mode and in the display the number of recordings not yet sent is shown together with a progress indication Fig 16 Fig 16 Send...

Страница 29: ...e transmission of one or several ECG fails immediately after recording the transmission process is repeated automatically The device repeats the transmission at the following time intervals first repe...

Страница 30: ...on is interrupted The ECG recording stays stored until the next transmission 5 4 Switching off the Device To switch off the device press the button 1 for longer than 10 seconds and hold it until the d...

Страница 31: ...es the data sent by the PhysioMem PM 100 via a mobile network converts these data to a defined data format and redirects them via a mobile network to a defined target address In ReSTA the device numbe...

Страница 32: ...n ECG recording is completed ReSTA sends a confirmation signal to the respective PhysioMem PM 100 and the ECG sent is deleted from the storage of the device 6 2 ECG Report The ECG report consists of t...

Страница 33: ...ation The device is not indicated to de tect Pauses automatically Fig 19 ECG report NOTE The recording and transmission times refer to Central European Time or Central European Summer Time CET or CEST...

Страница 34: ...ge 30 NOTE Check the charging state of the device if it has not been used for some time and charge the device as explained in the Putting into Operation Fully Charging the Battery section on page 20 N...

Страница 35: ...7 Meaning of Display Symbols and Audible Notifications 7 1 Display Symbols Condition Symbol Mobile transmission switched off No mobile network connection Mobile network found 0 to100 not connected Mo...

Страница 36: ...ng disturbed and deleted automatically No data transmitted Condition Capacity Symbol Charging of the battery required 0 to 10 Capacity display 20 40 60 80 100 Charging Sequence in 20 steps Ca pacity c...

Страница 37: ...nished success fully Rising sequence of 4 short beeps Confirmation REC BOOT Process has been started success fully 1 long beep Error REC Storage full 3 short beeps low frequency Recording in process R...

Страница 38: ...ction 4 2 ECG data cannot be transmit ted No mobile network con nection Data transmission will be re peated automatically If nec essary change location Device has not been acti vated by the manufac tu...

Страница 39: ...error code display E06 If the E06 error code is displayed contact the technical service E07 If the E07 error code is displayed you have to restart the device Press the button 1 for 10 seconds until t...

Страница 40: ...ele ECG Event Recorder 77212001 2 Wireless Charging Transmitter Pad 77442301 3 Power supply for wireless charging transmitter pad 77441101 4 USB cable for wireless charging transmitter pad 77412001 5...

Страница 41: ...e Charging method Inductive coupling with charging pad Operating mode 40 second ECG recording followed by data transmission User interfaces Start button LC Display acoustic buzzer Material ABSplasticc...

Страница 42: ...R value 1 95 W kg 10 5 Operation Conditions Temperature 5 to 45 C Relative humidity 10 to 95 non condensing Ambient pressure 106 to 50 kPa 106 to 80 kPa power supply 10 6 Storage and Transport Conditi...

Страница 43: ...c environment specified below The customer or the user should ensure that the device is used in such an environment Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11...

Страница 44: ...ply lines 1 kV for input out put lines 2 kV for power supply lines 1 kV for input output lines Mains power quality should be that of a typi cal commercial or hospi tal environment Surges IEC 61000 4...

Страница 45: ...50 60 Hz magnetic field IEC 61000 4 8 30 A m 30 A m Power frequency mag netic fields should be at levels characteristic of a typical location in a typi cal commercial or hospi tal environment NOTE UT...

Страница 46: ...15 MHz and 80 MHz 10 V m 80 MHz to 2 7 GHz Immunity against wire less RF com munication de vices 3 V effective value 6 V effective value in the ISM bands accord ing to table 5 Note N 10 V m according...

Страница 47: ...n 1 kHz Si nus 2 0 3 28 710 745 780 704 787 LTE Band 13 17 Pulse modula tion b 217 Hz 0 2 0 3 9 9 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modula tion b 18 Hz 2 0 3 28 1720 184...

Страница 48: ...or stacked with other equipment should be avoided because it could result in improper operation If such use is necessary this equipment and the other equipment should be observed to verify that they...

Страница 49: ......

Страница 50: ...Distributor Manufacturer GETEMED Medizin und Informationstechnik AG Oderstr 77 14513 Teltow Phone 49 3328 3942 0 Fax 49 3328 3942 99 Revision F 2020 05 11 info getemed de www getemed de...

Отзывы: