23
The following test results are possible:
Message
Description
Steam trap O.K.
The test object is in good working condition and not leaking
steam.
Defective
The test object is faulty.
Authorize qualified personnel to replace the faulty steam with a
new one.
FN (foreign noise)
The test object is affected by foreign noise. Consequently, the
test results are distorted.
Perform a foreign noise measurement (see page 26).
BC (banking-up of condensate)
The test object may be waterlogged. (This option is only
available if the required operating pressure of the test object
was entered in the system.)
Authorize qualified personnel to check the plant parameters and
the steam trap settings.
Cold
The temperature of the test object is below 40 °C.
Check the condition of the installation. Repeat the test when the
test object is operating.
Check
The mean value of the measured sound exceeds the limit sound
value. In addition one of the following conditions exists:
The temperature of the test object is below 40 °C.
The specified operating pressure of the test object does not
match the measured temperature.
The place of installation "Heat Exchanger" was selected.
Authorize qualified personnel to check the plant parameters and
the settings of the test object .
Comment
There is a comment on the test object.
Read the comment.