background image

9

1

) Physical and chemical properties comply with DIN grade.  ASTM nearest equivalent grade is

stated for guidance only.

Technical Data

Pressure/Temperature Rating

UNA 13  P

PMA (Max. allowable pressure)

[barg]

1

16

[psig]

230

TMA (Max. temperature)

with steel valve ball

[°C]

120

with Perbunan valve ball

[°C]

1

40

∆ 

PMX (Max. differential pressure)

with steel valve ball

[barg]

1

16

[psig]

230

with Perbunan valve ball

[barg]

1

16

[psig]

230

(inlet pressure minus
outlet pressure)

Materials

DIN

Body and
cover

new designation

old designation

Ball float

Seat

Valve ball

Body
gasket

Other
internals

EN-GJL-250

(EN-JL-1040)

Cast iron GG 25

(0.6025)

Austenitic stainless steel

X 6 CrNiMoTi 17122

(1.4571)

Stainless steel

X 8 CrNiS 189 (1.4305)

Stainless steel

X 5 CrNi 1810 (1.4301)

Graphite/CrNi

Stainless steel

ASTM

1

)

equivalent

A 126 CL.B

AISI 316 Ti

AISI 303

A 182 F 304

Содержание UNA 13P

Страница 1: ...1 UNA 13P Installation Instructions 810518 00 Air Trap for Compressed Air and Gas ...

Страница 2: ...nes 1 1 Differential pressure assuming discharge to atmospheric pressure Capacity of cold condensate 1000 800 600 500 400 300 200 100 80 60 50 40 30 2000 1000 800 600 500 400 300 200 100 80 60 0 1 0 2 0 4 0 6 1 2 3 4 5 6 8 10 16 0 3 0 5 0 8 1 2 3 4 6 8 10 20 30 40 60 80 100 200 lb h kg h psi bar ...

Страница 3: ...3 TOP Parts Drawings Fig 2 D E C F G H I J A B ...

Страница 4: ...4 Maintenance Fig 4 Fig 3 A I I ...

Страница 5: ...5 Flow direction arrow Body Cover Name plate 3 8 BSP connection for fitting an air balance pipe Gasket 17 x 23 Float lifting lever Handle Control unit Body gasket 77 x 67 x 1 Key B C D F G H I J A E ...

Страница 6: ... Danger 7 Important Notes Page Explanatory Notes Scope of supply 8 Description 8 Function 8 Technical data 9 UNA 13 Ph UNA 13 Pv 10 Air balance pipe 11 Installation Maintenance Clean air trap 11 Spare Parts Spare parts list 12 ...

Страница 7: ...ate to the istallation and commissioning of this device Danger The air trap is under pressure when the system is operating When loosening flanged connections or plugs fluid might escape Danger of serious injuries caused by gasket and trap parts that get loose abruptly Before carrying out any installation or maintenance work isolate and depressurize the trap The trap may be used in toxic fluids Thi...

Страница 8: ...e level in the trap The trap opens and closes independently of the temperature and pressure prevailing in the body Closing mechanism orifice for temperatures up to 40 C rolling ball valve made of Perbunan N up to 120 C made of steel Simplex design Closing mechanism with rolling ball valve of steel Simplex P design Closing mechanism with rolling ball valve of Perbunan N UNA 13 P is equipped with a ...

Страница 9: ...tial pressure with steel valve ball barg 116 psig 230 with Perbunan valve ball barg 116 psig 230 inlet pressure minus outlet pressure Materials DIN Body and cover newdesignation olddesignation Ball float Seat Valve ball Body gasket Other internals EN GJL 250 EN JL 1040 Cast iron GG 25 0 6025 Austenitic stainless steel X 6 CrNiMoTi 17122 1 4571 Stainless steel X 8 CrNiS 189 1 4305 Stainless steel X...

Страница 10: ...a space of 130 mm is required for removing cover 4 Remove plastic plugs They are only used as transit protection 5 Clean seating surfaces of both flanges 6 Install air trap Flanged Trap A C D 1 Take care of correct position of installation Name plate must always be on top 2 Take care of flow direction The flow arrow is on the trap body If necessary change direction of flow 3 Consider space require...

Страница 11: ...ily Maintenance 1 Remove cover from body Fig 2 2 Lever control unit off its support using a screwdriver Fig 3 3 Remove old gasket 4 Clean body and internals 5 Clean seating surfaces of body and cover insert new gasket 6 Position control unit on support and fix by two blows using a hammer and punch Fig 4 7 Insert new gasket and reassemble body and cover Tigthen body screws in diagonally opposite pa...

Страница 12: ...12 Spare Parts Spare Part List Item Designation Control unit Simplex Body gasket Orifice Control unit Simplex P Orifice 13 Orifice 13 Ref no 560415 560418 560493 I I J ...

Страница 13: ...13 ...

Страница 14: ...14 810518 00 300c 1999 GESTRA GmbH Bremen Printed in Germany ...

Отзывы: