Selecting a function
Before installation and bringing into service, please decide which function you
wish the NRGS 15-1 level switch to work with. Three functions are available:
Function 1
Default factory setting
Code switch
White toggle switch
Electrode rod 1
Low level 1 / burner off
Electrode rod 2
Low level 2
Electrode rod 3
Timed pump control (fill control) tv = 0 – 30 s
Electrode rod 4
High level
Function 2
Electrode rod 1
Low level alarm 1 / burner off
Electrode rod 2
Feedwater pump on (fill control)
Electrode rod 3
Feedwater pump off
(tv = 0 s)
Electrode rod 4
High level
Function 3
Electrode rod 1
Low level alarm 1
Electrode rod 2
Pump off
Electrode rod 3
Pump on (discharge control) (tv = 0 s)
Electrode rod 4
High level