21
NRGS 15-1 - USA - Installation & Operating Manual -
850690-00
Preparing for installation
If the equipment is to be installed outdoors, outside the protection of a building,
environmental influences may adversely affect function.
■
Pay attention to the admissible ambient conditions in the technical data,
see pages 12 and 13.
■
Do not operate the equipment if the temperature is below freezing.
◆
At temperatures below freezing, use a suitable heat source (e.g., control cabinet
heater, etc.).
■
Connect all parts of the plant to a central ground point to prevent equalizing currents.
■
Use a cover to protect the equipment from direct sunlight, condensation and
heavy rain.
■
Use UV-resistant cable ducts for routing the connecting cable.
■
Take further measures to protect the equipment from lightning, insects and animals,
and salty air.
You will need the following tools:
■
Open-ended wrench size 41
■
Scriber
■
Bolt cutter
■
Flat file
■
Phillips screwdriver PH2
■
Flat blade screwdriver 3/32 in (2.4 mm)