7
Original Instructions
Multi II
Technical specifi cations
Model
Multi 22
Multi 22 T Inox
Multi 30 T Inox
Multi 50 Inox
Container material
PP
INOX
INOX
INOX
Voltage (V)
220 - 240
220 - 240
220 - 240
220 - 240
P
NOM
(W)
1130
1130
1260
1260
P
max
(W)
1200
1200
1400
1400
Max Vacuum, kPa/bar
20/200
20/200
21/210
21/210
Max Suction power -
machine, W
270
270
292
292
Sound power
(EN 60704-2-1), dB(A)
85
85
87
87
Tank size, L
22
22
30
50
Net fi lling dry, in bag, L
9
9
13
20
Net fi lling liquid, L
14
14
20
36
Filter indicator
yes
yes
yes
yes
Push to Clean
yes
yes
Power out, max 1100
W
yes
yes
Auto on/off
yes
yes
Variable suction
control
yes
Operational instructions
Using the vacuum cleaner
On/Off - position “E”
Switch “0-I”
Switch position
Function
I
On
0
Off
Powertool Auto On/Off - position “A”
Switch “0-I”
Switch position
Function
I
On
0
Off
The machine provides two modes of operation:
vacuuming and blowing.
When using the machine for vacuuming, the hose is
connected to “G”. When using the machine for blow-
ing, the hose is connected to “H”.
The machine is turned on or off at switch “E”.
When running and operational the light in “B” will not
light. The light “B” will light when a drop in suction
performance occurs due to a dirty fi lter.
I
0
Cleaning the fi lter with Push to Clean*)
If the light “B” is turned on, the fi lter may be clogged.
1. Hold one hand against the end of the hose to form
a closed wall. Push the “Push to Clean” button “C”
for 2-3 seconds to let the machine clean the fi lter.
Wait for 3-5 seconds and repeat Step 1, max. 3
times.
2. If the indicator still lights, the cause may lie in a
too heavily clogged fi lter. Occasionally a light rinse
is suffi cient. If not, then replace the fi lter by a new
one.
Filter change (ref. illu. 4, page 2)
1. Open the machine so the fi lter is accessible.
2. Unscrew the tensioning plate “M” to release the
fi lter.
3. Remove the fi lter and replace it by a new one.
4. Tighten tensioning plate (turn right). Make sure
the threads on the tensioning plate are aligned
properly with the threads on the machine. Tighten
the tensioning plate fi rmly so the fi lter seals make
a closed connection to the machine. Beware not
to over-tighten the tensioning plate.
5. Assemble the machine again making sure the mo-
tor head has a proper fi t to the container.
Dust bag change
1. Open the machine so the dust bag is accessible.
2. Remove the old dust bag.
3. Gently slide the new dust bag over the angled
I
0