background image

*) 

Optional accessories / Option depending on model

Original instruction

11

Operating instructions

Troubleshooting MC 4M

Fault

Cause

Remedy

Pressure 

fl uctuations

Air in suction hose.

Fill hose with water and connect again

Not enough water supply

Stop! Until appropriate water mains or hose reflect 

pump Qmax

Water filter is clogged up

Rinse the water filter

High pressure nozzle blocked/worn   Clean or replace the nozzle with same size

Suction height exceeded

Stop! until max suction height is present as specified

Foam 

Sprayer 

not produc-

ing  foam 

Detergent used is non-foaming 

Use only detergents with foaming agent.

Nozzle on suction hose is clogged up 

or filled with dried out soap

Rinse detergent limiter / flush with tempered clean 

water.

Foam sponge in foam Sprayer is 

clogged up.

1 Rinse/soak foam Sprayer in tempered water for 8 

hours or more

2 Or dismount front of foam Sprayer and exchange/

rinse the SS foam sponge with a new

Detergent tank empty

Top up detergent tank

Motor does 

not start 

or bozzes 

when 

switched 

on

Power cable broken

Contact professional electrician for replacement of 

power cable 

Plug is not inserted in mains

Insert plug

Mains fuse is blown

Reset power mains

Plug has a loose connection to cable Repair/reassemble plug on cable - skilled electrician

The pump is blocked or frozen

Stop! Unfreeze pump or contact dealer service depart-

ment

The thermal protector is activated

Stop! Cool off machine for at least 5 minutes

Maintenance plan

Weekly

First time after 50 operating 

hours

Every 200 operating 

hours

As required

Cleaning 

water fi lter

A1.1

A1.1

Checking oil 

level/tip up

B1.0/E1.2

Changing 

pump oil

Contact dealer/service dpt.

Contact dealer/service dpt.

Special operating instructions

Self-suction

0: Dismount HP hose from the machine.
1: Fill the suction hose with water and connect to High 
Pressure Washer (Item no. 6400000)
2: Mount suction hose with a hose clamp on the pump 
inlet.
3: Turn main switch to ¨I¨ for few seconds. Repeat 
turning main switch on and off several times until water 
comes out of pump.
4: Mount the HP hose, spray handle and lance.
5: Turn main switch to ¨I¨.
6: Unlock the spray handle and operate it several times 
until water coming out without air.

Parts needed for suction

Item number

1 x Hose Nozzle 20R 3/4¨

61369

1 x Hose 3/4¨

Max length 5 mtr

1 x Hose Clamp 3/4¨

1 x Suction Filter with foot-valve

6400000

Содержание MC 4M

Страница 1: ...107145556 C 03 2015 MC 4M Operating instructions...

Страница 2: ...fe and in proper condition and in upright posi tion on a plain and stable ground to ensure stability Regularly check whether the power cord is damaged or shows signs of ageing WARNING Do not use the m...

Страница 3: ...r mains when an ap propriate backflow preventer has been installed Type BA according to EN 60335 2 79 The backflow preventer can be ordered under number 106411177 106411178 106411179 106411184 The len...

Страница 4: ...nded Always remove the plug from the mains plug socket before carrying out mainte nance work or cleaning of the machine Carry out only the maintenance operations described in the operating instruction...

Страница 5: ...5 A 6 5 13 18 19 21 20 15 1 3 4 7 8 9 10 11 14 17 2 16 12...

Страница 6: ...6 1 4 1 5 1 3 1 1 1 2 B O I 1 0 1 1 1 2 1 3 1 4 BA Valve BA Valve...

Страница 7: ...7 1 1 1 2 1 3 1 0 MAX CHEM 3 0 MIN MIN C 4 0 4 1...

Страница 8: ...8 1 0 1 2 O I 1 1 1 3 1 4 8 1 1 6 MAX MAX 5 1 MC 4M D...

Страница 9: ...9 E 10 2 1 2 1 3 1 1 1 0...

Страница 10: ...unit 1 1 Mount filter and Gardena coupling 1 2 Mount the seal and 3 8 nipple on high pressure outlet 1 3 Connect hoses water and high pressure hose 1 4 Mount the lance 1 5 Connect the electrical cable...

Страница 11: ...for replacement of power cable Plug is not inserted in mains Insert plug Mains fuse is blown Reset power mains Plug has a loose connection to cable Repair reassemble plug on cable skilled electrician...

Страница 12: ...5 1 2012 EN 60335 2 79 2012 EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 11 2000 EN 50581 2012 Following the provisions of Machinery Dir...

Страница 13: ...ure bar MPa 200 20 8 QMAX Water flow l h 620 9 tmax Max water inlet temperature Intake Pressure operation C F 60 40 max 1 h 140 104 max 1 h 10 pmax Max water inlet pressure bar MPa 10 1 11 Max dry suc...