1 Introduction

1.1  Symbols used to mark  instruction

All pictograms attached to the high pressure washer and its components are shown and ex-
plained in this manual.

Safety instructions marked with this symbol must be observed to prevent personal injury or 
serious damage to property.

Caution where there is a risk of damaging the machine or its individual components. 

This symbol indicates tips and instructions to simplify work and to ensure a safe operation of 

the high pressure washer.

2  Safety precautions and working techniques

Before starting up your machine for the fi rst time, this instruction manual must be read through 
carefully. Save the instructions for later use.

 WARNING! 

• Inhalation of aerosols can be hazardous to health. 

Where applicable use a device in order to avoid or re-
duce aerosols production, e.g., a shield covering the 
nozzle. For protection against aerosols use a respira-
tory mask of class FFP 2 or higher.

• The high water pressure generated by the machine 

and the power connection are particular sources of 
danger.

• Children should be supervised to ensure that they do 

not play with the machine.

• Before starting up your machine please check it care-

fully for any defects. If you fi nd any, do not start up 
your machine, contact your Gerni  distributor. The in-
sulation of the electric cable should be faultless and 
without any cracks. If the electric cable is damaged, 
an authorized Gerni di stributor should replace it.

• The operator and anyone in the immediate vicinity of 

the site of cleaning should take action to protect them-
selves from being struck by debris dislodged during 
operation.

• Always unplug the power plug before cleaning or 

maintenance and when replacing parts or converting 

Содержание Classic 100.3

Страница 1: ...128331922 b 03 2014 Classic 100 3 Classic 100 3 S Classic 110 4 Classic 115 3 Classic 120 4 User Guide Classic 100 3 Classic 100 3 S Classic 110 4 Classic 115 3 Classic 120 4 Why compromise...

Страница 2: ...Printed in China Copyright 2014 Gerni...

Страница 3: ...3 2 Mounting of quick coupling 10 4 Operating your high pressure washer 11 4 1 Connection of high pressure hose 11 4 2 Mounting of spray lance and Click Clean nozzles 11 4 3 Water Connection 11 4 4 S...

Страница 4: ...applicable use a device in order to avoid or re duce aerosols production e g a shield covering the nozzle For protection against aerosols use a respira tory mask of class FFP 2 or higher The high wate...

Страница 5: ...ith reduced physical senso ry or mental capabilities or lack of experience and knowledge Anyone who has consumed alcohol medicines or drugs affecting their ability to react must not operate the machin...

Страница 6: ...arts of the machine are damaged e g safety de vice high pressure hose and spray handle and spray attachments The trigger of the spray handle must move easily and automatically return to its starting p...

Страница 7: ...f the electric cable is damaged it must be replaced by an authorized Gerni distributor or similar qualified person in order to avoid a hazard Water connection This high pressure washer is only allowed...

Страница 8: ...jet at live electrical equipment or the machine itself danger of short circuiting Hold the spray lance firmly with both hands The spray lance is affected by a thrust of up to 16 4 N during operation T...

Страница 9: ...be made in Gerni authorized workshop with original Gerni spare parts Do not attempt any maintenance not described in the instructions If the machine refuses to start stops pulsates pres sure fluctuate...

Страница 10: ...Classic 110 4 Classic 115 3 Classic 120 4 A1 Place the trolley handle 15 on the machine A2 Secure the handle by mounting the 2 screws using the enclosed hexagon key 17 Mounting of wheel brackets Only...

Страница 11: ...an nozzles and the foam sprayer IMPORTANT Before starting the cleaning job check that the machine is in an upright position and placed on an even surface Do not place the machine in long grass 4 3 Wat...

Страница 12: ...k the trigger when leaving the high pressure washer unattended B12 Activate the trigger of the spray handle and let the water run until all air has escaped from the water hose B13 Turn on the machine...

Страница 13: ...d only be used when the nozzle is detached and the ma chine is stopped D2 Stop the machine and disconnect the nozzle Clean the nozzle D3 Flush the nozzle backwards with water Cleaning of machine vents...

Страница 14: ...iption specification of the fault and the original purchase receipt or a copy must be enclosed Packing and postage carriage is not covered by the warranty Symptom Cause Recommended action Machine stop...

Страница 15: ...ty assistance only after checking possible causes in the trouble shooting chart on page 13 9 Main technical Data Type Classic 100 3 Classic 110 4 Classic 115 3 Classic 120 4 Electric specifications Ra...

Страница 16: ...55014 2 1997 A1 2001 A2 2008 Electromagnetic compatibility Requirements for household appliances electric tools and similar apparatus Part 2 Immunity Product family standard EN 61000 3 2 2006 A1 2009...

Страница 17: ...Classic 120 4 Classic 115 3 I O...

Страница 18: ...A7 A8 A5 A6 A3 A4 A1 A2 2 2a 3 14 Classic 110 4 Classic 100 3 Classic 100 3 S 18 19 20...

Страница 19: ...C3 C5 C5 C4 C3 C2 C1 C1 B14 B13 B11 B12 B10 B9 B2 B1 B8 B6 B7 I O B3 B4 B5 Max 40 C Max 40 C...

Страница 20: ...D5 D4 D3 D2 D1...

Страница 21: ...Advance Pty Ltd Unit 1 13 Bessemer Street Blacktown NSW 2148 Phone 1300 556 710 E mail sales gerni com au NEW ZEALAND Accent Tools Ltd 232 Bush Rd Albany Auckland 0632 Phone 09 968 2610 E mail sales a...

Отзывы: