WARNINGS &  SAFETY PRECAUTIONS

 

WARNING!

• 

Read all instructions carefully before using this product.

• 

This product is not intended for use by children or persons with reduced physical, sensory 
or mental capabilities, or lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of this product by a person responsible for their safety.

• 

Mind your children and DO NOT let children play with this product.

• 

Cleaning and user maintenance shall not be made by children without supervision.

• 

Check the “Gas type”, “Gas working pressure”, “Rated heat input” indicated on the rating label 
before using this product.

• 

This product is for domestic indoor use only.

• 

If the gas connection piping is damaged, it must be replaced by the manufacturer, its service 

agent or similarly qualified persons in order to avoid hazards.

• 

Make sure the ignition knob is at “

” position and the gas cooker has completely cooled down 

before cleaning and maintenance.

• 

Contact German Pool authorized service technician for repair or maintenance of this product.

Notice Before Use

Important

For safety purposes, you should read the instructions carefully before using the appliance for the first 

time. Save the instructions for future reference.
The appliance is designed for domestic use and may only be installed and operated in accordance with 
these instructions for use.
1.  The cooking range must be installed by registered gas installers.
2. 

Ensure that the cooking range is used with good ventilation. Environment with insufficient oxygen 

should be avoided.

3.  This built-in range is to be used for cooking only. DO NOT dry towels, clothes etc. over it.
4.  During long period of use, open window or exhaust fan to ensure good ventilation.
5.  Check that all control knobs have been set to “

” position after use.

6. 

If the flame is blown out during use, the safety valve will cut off gas supply. Ignite again after at 

least 1 minute.

7. 

Take extra care when cooking oil or fat. High temperature of oil or fat may cause fire hazard.

8. 

To avoid hazard, DO NOT use spray or compressed gas when the cooking range is in use.

9. 

After ignition, check if the flame is even and normal. Before removing cookware away from the 
flame, always set to small flame or “

” position.

10.  To avoid damage to the cooking range, DO NOT place any hot mat between the range rack and the 

utensil.

11.  DO NOT use burner rack other than the one provided. Otherwise, it will cause overheat to the 

range surface.

12. 

DO NOT use over-size or over-weight utensils. Or it will cause excessive heat to be reflected back 

onto the range surface.

13.  Place the utensil steadily on the range rack. DO NOT tilt the utensil.
14.  Contact German Pool Customer Service and Repair Centre for repair and parts replacement. 

During guarantee period, German Pool resrves the right to charge for spare parts and service fees 
if the damage is caused by misuse or improper installation.

Содержание GP13 Series

Страница 1: ...6 Please read these instructions and warranty information carefully before use and keep them handy for future reference Online Warranty Registration U S E R M A N U A L Built in Gas Cooking Range GP13...

Страница 2: ...ontents Warnings Safety Precautions Product Structure Installation Instructions Operation Instructions Cleaning Maintenance Troubleshooting Technical Specification Warranty Terms Conditions 03 05 07 1...

Страница 3: ...nstructions for use 1 The cooking range must be installed by registered gas installers 2 Ensure that the cooking range is used with good ventilation Environment with insufficient oxygen should be avoi...

Страница 4: ...with glass top panel should also be noted in order to prevent the glass top panel from breaking Clean the burner assembly frequently to maintain a clear gas passage on the flame distributor Clean and...

Страница 5: ...ss Panel Body Gas Inlet Joint Burner Rack Drip Pan Burner Head H Knob Battery Box bottom of unit GP13 2 TG GP13 2 LG Burner Cap Burner Ring Sparker Flame Sensor Glass Panel Body Gas Inlet Joint Burner...

Страница 6: ...ass Panel Body Burner Cap Burner Ring Flame Sensor Drip Pan Glass Panel Body Gas Inlet Joint Burner Rack Drip Pan Burner Head H Knob Battery Box bottom of unit Gas Inlet Joint Burner Rack Sparker Burn...

Страница 7: ...king range and the countertop cabinet shelf board below External gas governor is not required I Room Ventilation The kitchen should have no less than 20m air volume for regular gas combustion and be k...

Страница 8: ...necting from inch B S P thread at back of the unit to the gas supply point Stainless steel braided flexible hose connection please use approved stainless steel braided flexible tubing bearing EMSD app...

Страница 9: ...head to deform or the glass may break or increase the risk of releasing carbon monoxide CO Burner Ring Burner Cap Burner Head Base Gap Burner Head Base Fig 2 Fig 3 IV Correct Position of Burner Rack...

Страница 10: ...seconds 2 If the flame goes out when you release your hand repeat the ignition procedure again but try releasing your hand slowly 3 Turn Control Knob to adjust flame to desirable setting 4 Turn the C...

Страница 11: ...too low Ports of burner cap are clogged Air hole is not properly adjusted Open gas valve or change gas supply Prolong ignition time and repeatedly ignite till air is vented out Straighten gas hose Co...

Страница 12: ...as 1500 Pa L 6 0kW R 6 0kW DC 1 5V x 1 Impulse Ignition System Yes 125 H x 750 W x 450 D 15 kg H K LP Gas 2900 Pa L 5 0kW R 5 0kW Model GP13 2M TG GP13 2M LG Gas Type Gas Working Pressure Rated Heat I...

Страница 13: ...P 13 14 15 17 20 21 21 22 23...

Страница 14: ...P 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 34cm 10...

Страница 15: ...P 15 GP13 3 TG GP13 3 LG GP13 2 TG GP13 2 LG...

Страница 16: ...P 16 GP13 2M TG GP13 2M LG GP13 1 TG GP13 1 LG...

Страница 17: ...P 17 15 6 15 25 1 I 20m 100c II A EMSD APPROVAL GTXXXX EMSD APPROVAL GTXXXX B S P B EMSD APPROVAL GTXXXX B S P...

Страница 18: ...P 18 III R GP13 3 TG GP13 3 LG GP13 2 TG GP13 2 LG GP13 2M TG GP13 2M LG GP13 1 TG GP13 1 LG 815 665 463 265 405 345 342 490 50 50 D W R...

Страница 19: ...P 19 1 2 3 B 2 3 IV A 1...

Страница 20: ...P 20 4 5 1 6 8 2 3 4 4 5 6 5...

Страница 21: ...P 21 1 5 x1...

Страница 22: ...5 0kW 1 6kW 5 0kW GP13 2 TG GP13 2 LG 1500 Pa 6 0kW 6 0kW DC 1 5V x 1 125 x 750 x 450 15 kg 2900 Pa 5 0kW 5 0kW GP13 2M TG GP13 2M LG 1500 Pa 6 0kW 1 6kW DC 1 5V x 1 125 x 580 x 380 10 8 kg 2900 Pa 5...

Страница 23: ...part 5 This warranty will be void if there is any transfer of ownership from the original purchaser 1 2 3 4 5 Serial No Purchased From Invoice No Purchase Date Model No Please fill out the form below...

Страница 24: ...9 6809 8th Xinxiang Road Wusha Industrial Park Daliang Shunde Foshan Guangdong 3 F Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel 853 2875 2699 Fax 853 2875 2661 Macau All...