2  Preparation and Installation 

2.1 Safety 

information 

The 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

X

X

4

4

S

S fixtures from GLP is fitted with a number of plano-

convex lenses in a highly efficient collimator cluster. This type of lens can act as 

a strong magnifying glass. 

If the rays from a strong light source (such as the sun or another lighting fixture) 

are directed towards the front of any of these fixtures, then internal damage 

may occur. In a worst case scenario with a high power light source this can 

happen very quickly, damaging the fixture internally, potentially melting 

components or causing an internal fire within seconds.  

In order to avoid these possible problems please adhere to the following 

requirements: 

• 

Do not expose the front of a fixture to direct sunlight or any other strong 

light sources. 

• 

For outdoor applications during daylight make sure that the front face of 

any fixture is either shielded or points away from the sun, even when 

fixtures are not in use. 

• 

Do not modify the front glass or lenses of any fixture.  

These requirements have to be followed regardless of whether a fixture is 

powered on or off as the magnifying effect is an optical effect and therefore 

independent from the (electrical) state of the fixture. 

Especially when working with high powered 

b

b

e

e

a

a

m

m

-

-

l

l

i

i

g

g

h

h

t

t

s

s; extreme caution and 

observance of these safety instructions is mandatory. 

 

Should you have any questions about the operation of your fixture then please 

contact your local GLP office, or their authorized distributor, a list of which can 

be found at http://www.glp.de. 

Содержание impression X4S

Страница 1: ...Instruction Manual from software version V1 09 Instruction version 1 1 e mail service glp de Internet http www glp de ...

Страница 2: ...GLP German Light Products GmbH Instruction version 1 1 from software version V1 09 2 Notes ...

Страница 3: ...oor Upright 8 2 2 2 Mounting in hanging position 8 2 2 3 Mounting in sideways Position 8 2 3 Securing the Fixture 9 2 4 Connections 9 2 4 1 Power Supply 9 2 4 2 DMX 9 3 The Menu Field 10 4 DMX Channel Selection DMX Protocol 12 5 Maintaining and Cleaning the I IM MP PR RE ES SS SI IO ON N X X4 4S S 16 5 1 Safety regulations 16 5 2 Maintenance and Interval rule of thumb 16 5 3 Changing the Fuse 17 6...

Страница 4: ... Device 1 Moving head actively and passively cooled 2 Arm of device 3 LCD Display Menu data entry 4 Base with various connectors air in outlets and mounting system 5 Fuse holder 1 2 3 4 5 ba se sid e 1 6 7 base s id e 2 8 9 6 Power On Off 7 DMX Output 5 pin 8 DMX Input 5 pin 9 Mains supply fixed cable ...

Страница 5: ... necessary to wait at least 15 minutes after disconnecting the mains power before handling the fixture Pay attention to possible hot parts of the fixture Danger of BURNING 6 Never look directly into the beam of light or into one of the LEDs Never use optical apertures to observe the beam of light LED Class 2M You ll risk serious injury of your eyes and in particular of your retina Attention LED Cl...

Страница 6: ...id these possible problems please adhere to the following requirements Do not expose the front of a fixture to direct sunlight or any other strong light sources For outdoor applications during daylight make sure that the front face of any fixture is either shielded or points away from the sun even when fixtures are not in use Do not modify the front glass or lenses of any fixture These requirement...

Страница 7: ...C1 former VBG 70 DIN VDE 0711 217 and BGI 810 3 The installation shall be done by qualified staff only For the various mounting positions of the I IM MP PR RE ES SS SI IO ON N X X4 4S S standing on the floor sideways or hanging different connectors are available Through this a safe and firm installation is assured You ll find dedicated M10 threads on the bottom side of the fixture which should be ...

Страница 8: ...clamp This can be mounted directly to the bottom side of the fixture It should be attached centrically with a M10 mm thread bolt max length 11mm Attention Never use a longer bolt as this may damage the interior of the fixture 2 2 3 Mounting in sideways Position To operate the I IM MP PR RE ES SS SI IO ON N X X4 4S S in a sideways position please use two half couplers clamps attached to the bottom ...

Страница 9: ... structure Pay attention to a safe and proper fastening The safety cable must comply with BGI 810 3 EN 60598 2 17 Section 17 6 6 and be capable of bearing a static suspended load that is ten times the weight of the fixture and all installed accessories 2 4 Connections 2 4 1 Power Supply 100 240 Volt AC 50 60 Hz earth contact type plug Connected load 130 VA W T5A micro fuse 5x20mm Please see printi...

Страница 10: ...an Manual control for Pan X movement Pattern Byte 1 Manual control for Pattern Byte 1 LED 1 7 Pattern Manual control for Pattern channel bank Zoom Manual control for Zoom Speed Movements Manual control for Pan Tilt movements Pan Tilt Movements Manual control for Pan Tilt movements Special White Temperature Manual control for Color temperature Dimmer Manual control for Dimmer Shutter Manual control...

Страница 11: ...for Pan Tilt movements Special Instantaneous value for Special White Temperature Adjustment of the color temperature for WHITE Dimmer Instantaneous value for Dimmer Shutter Instantaneous value for Shutter White Instantaneous value for White Blue Instantaneous value for Blue Green Instantaneous value for Green Red Instantaneous value for Red Color Wheel Instantaneous value for Color Mixing unit Set...

Страница 12: ... 80 50 Rainbow Effect 3 slow fast 129 223 81 DF 51 88 Random colors slow fast 224 255 E0 FF 89 100 6 Red Color mixing system Red 0 100 0 255 00 FF 0 100 7 Green Color mixing system Green 0 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9 White Color mixing system White 0 100 0 255 00 FF 0 100 10 Shutter Shutter closed 0 15 00 0F 0 5 5 Shutter pulse random slow fast 1...

Страница 13: ... 224 255 E0 FF 88 100 15 Speed Pan Tilt movement speed from controller 0 1 00 01 0 0 5 Pan Tilt Pan Tilt slow fast Use this channel also for the speed of the movements channel 14 02 255 02 FF 1 100 16 Zoom Wide narrow spot 0 255 00 FF 0 100 17 Pattern No pattern 0 2 00 02 0 1 Pre defined patterns 03 253 03 FD 2 99 Activates direct access to LED Pattern 254 255 FE FF 100 18 Pattern Byte 1 Direct ac...

Страница 14: ... Random Pulse effect slow fast 16 47 10 2F 6 18 5 Up dimming then Shutter closing random patterns slow fast 48 79 30 4F 19 31 5 Shutter open then down dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 249...

Страница 15: ...rse Dimmer 0 100 0 255 0 FF 0 100 15 Dimmer fine Dimmer Low 0 255 0 FF 0 100 16 Zoom Spot Flood 0 255 00 FF 0 100 17 Special Pattern Block 1 channel 18 0 3 00 03 0 1 Change PWM frequency 100 200 64 C8 40 78 RESET 250 255 FA FF 98 100 18 Pattern No pattern 0 2 00 02 0 1 Pre defined patterns 03 253 03 FD 2 99 Activates direct access to LED Pattern 254 255 FE FF 100 19 Pattern Byte 1 Direct access to...

Страница 16: ...n it is absolutely essential that the fixture is kept clean and that dust dirt and smoke fluid residues must not build up on or within the fixture Otherwise the fixture s light output will be significantly reduced or damages can occur Regular cleaning will not only ensure the maximum light output but will also allow the fixture to operate reliably throughout its life A soft lint free cloth moisten...

Страница 17: ... Fuse Follow the safety regulations as described above The micro fuse holder 2 is located on the topside of the base In order to attain access you first need to remove one of the two plastic side covers of the fixture arm Open the two screws no 1 shown in the picture below Replace the fuse with one with the exact rating as printed in this manual or the body of the fixture Never use a different one...

Страница 18: ...r space Optical System Full RGBW High efficient Collimator cluster Shutter Dimmer 8 16 Bit Strobe Effect with variable speed between 1 10 flashes per second Random Strobe Pulse Effects Continuous Dimmer 0 100 Zoom 7 to 50 degree continuous zoom Optical Patterns Several hundred pre defined beam patterns with direct access and manipulation DMX Control Standard USITT DMX 512 5 pin XLR Pin 3 Pin 2 Gro...

Страница 19: ...GLP German Light Products GmbH Instruction version 1 1 from software version V1 09 19 7 Dimensions 3x M10 length max 11mm ...

Страница 20: ...ode 14 I Instruction Version 1 Internet 1 L LED Class 2M 5 M Maintenance 16 Menu Field 10 Micro fuse 9 Mode key 10 Mounting 7 Mounting in hanging Position 8 Mounting in sidewise Position 8 Mounting on the Floor 8 N Normal Mode 12 O Optical parts 17 P Pan Movement 18 plano convex lenses 6 Power Supply 9 R RESET 12 S Safety distance 7 Safety information 6 Safety Instructions 5 Secure the Device 9 So...

Страница 21: ...GLP German Light Products GmbH Instruction version 1 1 from software version V1 09 21 ...

Отзывы: