GLP
German Light Products GmbH
(Instruction version 1.97) / from software version 1.61
29
5.2 Maintenance Intervals (rule-of-thumb)
The maintenance schedule of any given fixture depends on the installation
environment. Hence no specific guidelines can be given. The cleaning intervals
given below are suggestions, based on practical experience. We suggest that
you start with these and develop your own maintenance schedule as you see
the fixtures performance in your specific environment.
Maintenance Task
Interval
How
Outside optic
weekly
soft cloth and glass cleaning fluid
Gobos
yearly
vacuum cleaner, airbrush, etc.
Glass gobos
yearly
soft cloth and glass cleaning fluid
Prism
yearly
soft cloth and glass cleaning fluid
Iris
yearly
vacuum cleaner, airbrush, etc.
Inside lens
yearly
soft cloth no glass cleaning fluid
Fan and air channel
monthly
vacuum cleaner, airbrush, etc.
Moveable parts
yearly
suitable fatty oil
Attention:
•
Never let optical parts come into contact with oil or fat.
•