LIMITED WARRANTY

Warranty Claims...

All Claims for parts or labor must be made directly through German Knife or Radiance. All claims should include the model number, serial 

number, proof of purchase, date of installation and all pertinent information supporting the alleged defect. All warranty claims must be 

authorized by German Knife or Radiance prior to the purchase of parts or labor. Failure to comply with these warranty policies will result in 

the voiding of warranty claims. 

Products Under Warranty...

Radiance warrants all heavy duty microwaves to include all new parts and components to be free from defects in material or workmanship 

under normal and proper use and maintenance service as specified by Radiance upon proper commercial installation. Radiance’s 

obligation under this warranty is limited to a period of three (3) years from the date of original purchase. Any Part covered under this 

warranty that is found by Radiance to have been defective within 3 years of the original purchase is limited to the repair or replacement, 

including labor charges, of defective parts or assemblies. The labor charges shall include standard straight time labor charges only and 

reasonable travel time as determined by Radiance. 

Radiance warrants all gas cooking equipment and microwave models TMW-1100MR and TMW-1100ER and German Knife warrants all 

light duty meat slicers  to include all new parts and components to be free from defects in material or workmanship under normal and 

proper use and maintenance service as specified by German Knife upon proper commercial installation. German Knife’s obligation under 

this warranty is limited to a period of one (1) year from the date of original purchase.  Any Part covered under this warranty that is found by 

German Knife to have been defective within 1 year of the original purchase is limited to the repair or replacement, including labor charges, 

of defective parts or assemblies. The labor charges shall include standard straight time labor charges only and reasonable travel time as 

determined by German Knife. 

German Knife warrants all heavy duty meat slicers, meat grinders, and meat saws to include all new parts and components to be free 

from defects in material or workmanship under normal and proper use and maintenance service as specified by German Knife upon 

proper commercial installation. German Knife’s obligation under this warranty is limited to a period of two (2) years from the date of 

original purchase. Any Part covered under this warranty that is found by German Knife to have been defective within 2 years of the original 

purchase is limited to the repair or replacement, including labor charges,  of defective parts or assemblies. The labor charges shall include 

standard straight time labor charges only and reasonable travel time as determined by German Knife. 

What is Not Covered by This Warranty...

German Knife’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations 

below. This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this 

warranty.

No consequential damages. Radiance is not responsible for economic loss; profit loss; or special, indirect, or consequential damages. 

Warranty is not transferable, this warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered.  

Any such assignment or transfer shall void the warranties herein and shall void all warranties, express or implied, including any warranty 

of merchantability or labor coverage for component failure or other warranty packet provided with the unit. 

Alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, food, acts of god. German Knife is not responsible 

for the repair or replacement of any parts that radiance determines have been subjected after the date of manufacture to alteration, 

neglect, abuse, misuse, accident, damage during transit or installation, fire, flood, or act of god.  Improper electrical connections. German 

Knife is not responsible for the repair or replacement of failed or damaged components resulting from electrical power failure, the use of 

extension cords, low voltage, or voltage drops to the unit. No implied warranty of merchantability or fitness for a particular purpose; there 

are no other warranties, expressed, implied or statutory, except the warranties expressly granted above. These warranties are exclusive 

and in lieu of all other warranties, including implied warranty and merchantability or fitness for a particular purpose. There are no warran-

ties, which extend beyond the  description on the face hereof.

Outside U.S. and Canada; this warranty does not apply to, and radiance is not responsible for, any warranty claims made on products sold 

or used outside the continent of the United States and Canada.

Содержание GS-12A

Страница 1: ...nc com IMPORTANT SAFETY NOTICE To ensure safe and trouble free performance of you new German knife slicer we suggest that all personnel who will use and maintain the slicer read and understand the manual before operating the equipment Should there be any questions or if we can be of further assistance please call us toll free at 800 500 3519 ...

Страница 2: ...ions Manual Operation Automatic Operation Cleaning Knife Sharpening Simple Maintenance and Repair Optimal Slicing Performance Troubleshooting Guide Warranty Information 3 4 5 6 8 9 10 12 17 20 22 23 24 PAGE German Knife Industries 4184 E Conant St Long Beach CA 90808 Phone 800 500 3519 Fax 310 900 1066 www turboairinc com ...

Страница 3: ...ction of this equip ment particularly the sharp knife and all moving parts If you are uncertain about a particular task or the proper method of operating this equipment ask your supervisor This manual contains a Safety Tips Section listing a number of precautions to follow to help promote safe use of this equipment Throughout the manual you will see additional warnings to help alert you to potenti...

Страница 4: ... Handle Slice Thickness Dial Auto Engage Lever Knife Control Panel Knife Motor Start Stop Touch Pad Controls Chute Speed Touch Power Indicator Light Auto Engage Lever Rubber Feet Knife Cover Oil Hole Name Plate Lift Lever Receiving Area Start Stop Switch Speed Display Chute Speed Controls Knife Ring Guard Knife Motor Slicer Table Chute Arm ...

Страница 5: ...ORE TURNING SLICER ON place auto engage lever in MANUAL position Automatic slicers only ONLY USE FOOD CHUTE HANDLE to push food chute during manual slicing ONLY USE THE END WEIGHT NOT YOUR HAND to hold food products when slicing Never put your hand on or around food chute when slicer is on DO NOT CATCH SLICES WITH YOUR HAND Let slices drop on paper covered receiving area USE ONLY GERMAN KNIFE SLIC...

Страница 6: ...ed save the packaging material and contact the carrier within 24 hours of delivery Immediately contact the shipper You have no recourse to damage after 24 hours You should receive with the slicer rubber feet mineral oil owner operator manual and wall chart Contact German Knife or your supplier if you did not receive all of these materials 1 Read this manual thoroughly before installation and opera...

Страница 7: ...r slicer Place the Spanish labels on the slicer if your work force requires them 10 Complete warranty card and mail to German Knife service center 11 Clean the slicer using the procedures outlined in the Cleaning Section page 13 through 16 prior to using the slicer 12 Contact your local representative or German Knife directly if you have questions or problems regarding the installation or operatio...

Страница 8: ...DLE to push food chute during manual slicing ONLY USE THE END WEIGHT NOT YOUR HAND to hold food products when slicing Never put your hand on or around food chute when slicer is on DO NOT CATCH SLICES WITH YOUR HAND Let slices drop on paper covered receiving area BE ALERT that food chute moves back and forth during automatic operation and can move in either direction on start up ALWAYS turn off sli...

Страница 9: ...on The power indicator light will illuminate 6 Use the food chute handle to manually push the food chute back and forth The food chute handle is the only part of the slicer you should touch while slicing Do not catch slices with your hand Let slices drop on paper covered receiving area 7 After the last slice stroke pull food chute all the way toward you and turn the slicer off by pressing the on o...

Страница 10: ...atically and it can move either direction on start up Never attempt to adjust load or unload food chute when slicer is in the automatic mode 4 Auto Engage Lever must be in MANUAL position to start the slicer 5 Press start button the power indicator light will illuminate The speed indicator light will flash 4 if the start button is pressed when the Auto Engage Lever is in the automatic position Low...

Страница 11: ...te Handle pull the food chute all the way toward the operator Turn slice thickness dial all the way clockwise to close the slicer table Now you can load and unload the product 10 When finished using slicer make sure slicer is turned OFF the slice thickness dial is turned completely clockwise and the Auto Engage Lever is in the MANUAL position CAUTION The knife is still rotating even though the chu...

Страница 12: ...ove chute and unplug slicer NEVER attempt to clean slicer with the knife running NEVER attempt to remove knife or knife ring guard for cleaning Your slicer should be cleaned and sanitized as often as necessary or at least once per day Slicer components are easily disassembled without the use of special tools NOTE It may be desirable to wear cut resistant glove during the cleaning operation ...

Страница 13: ... cover 6 KNIFE COVER While holding the knobs on the knife cover pull up on the top spring loaded knob and lift upward to move Figs 11 1 11 2 Slicer will not start with knife cover removed DISASSEMBLY CLEANING BE ALERT THE NEXT STEPS WILL EXPOSE THE KNIFE NEVER ATTEMPT TO REMOVE OR DISMANTLE THE KNIFE RING GUARD NEVER TRY TO REMOVE THE KNIFE FROM THE SLICER IT MUST REMAIN ON THE SLICER FOR PROPER O...

Страница 14: ... 7 The knife ring guard must now be cleaned To clean the knife ring guard soak a clean cloth in a mild detergent and warm water solution Ring out excess water from cloth Carefully insert the cloth between the knife and the knife ring guard as indicated by Fig 12 1 While holding the cloth between the knife and the knife ring guard work it along the entire back side of the knife between the knife an...

Страница 15: ...he bottom notches of the knife cover with the knobs located at the bottom of the knife ring guard Fig 13 1 The top right of the knife cover also has a hole that fits over a locator pin at the top of the knife ring guard 10 Lower the knife sharpener cover 11 With the slicer table completely closed wipe the slicer table off by starting at the knife and pulling towards you Never wipe the slicer table...

Страница 16: ...toward the front of the slicer and lower the unit Fig 14 1 3 Some automatic slicers have a lift lever which raises the slicer to allow cleaning underneath To clean under a slicer equipped with a lift lever a With the Auto Engage Lever in MANUAL position push the food chute to the back of the slicer b Pull the lift lever knob toward operator with your right hand while gently lifting up on the slice...

Страница 17: ...ER sharpen slicer unless all guards are installed ALWAYS make sure food chute is removed and Auto Engage Lever is in MANUAL position when sharpening automatic slicer GENERAL 1 Symptoms of a dull knife are excess waste or tail on the unsliced portion remaining in the food chute 2 The knife needs to be sharpened periodically to provide consistent slices and maximum food product yield Sharpening the ...

Страница 18: ...harpener stones by lifting the knife sharpener cover Figs 16 1 16 2 Stones should be clean dry and free of dirt and grease Turn slicer off by pressing the stop button Automatics only or by pushing the on off tab inward ALWAYS keep hands and arms away from exposed knife Make sure slicers have the food chute removed Make sure Auto Engage lever is in MANUAL position Automatics units only BE ALERT The...

Страница 19: ...ics only or by pressing the on off switch button Unplug the power cord 2 Return the sharpener to its original position by pulling on knob 1 keeping it extended Also hold onto lever 2 and swing sharpener back in to stored position Fig 17 4 3 If sharpening stones need to be cleaned use alcohol and a brush Dry stones afterwards 4 Close sharpener cover 5 Clean slicer as necessary using cleaning proced...

Страница 20: ...lockwise remove chute and unplug slicer NEVER touch this machine without training and authorization from your supervisor You must be at least 18 years old Read owner and operator manual first NEVER TOUCH KNIFE Keep hands and arms away from all moving parts DO NOT temper with bypass or remove any safety devices guards or touch pad controls ALWAYS turn off slicer return auto engage lever to MANUAL p...

Страница 21: ...il on slide rods underneath E Wipe off excess oil 1 Chute Slide Rods A The end weight slide rod 1 Fig 19 2 should be lubricated as needed with a few drops of mineral oil 2 End Weight Slide Rod A The sharpener shafts should be lubricated once per month with a few drops of mineral oil B Add mineral oil to each of the sharpener shaft behind the stone where the shaft enters the sharpener housing 3 Sha...

Страница 22: ...e knife is sharpened and the diameter is reduced a It will be necessary to have the table adjusted inward toward the knife in order to maintain a consistent 1 32 clearance between the table and knife b It will be necessary to have the sharpener assembly adjusted lower to maintain proper alignment with the knife We recommend an authorized German Knife Service Company to perform all adjustments and ...

Страница 23: ... have new knife installed Install knife cover Install knife cover Press stop button to remove flashing 2 wait 10 min and restart slicer Knife cover removed or not properly installed Knife cover removed or not properly installed Knife slicer table gap too wide knife too small 11 1 4 or less Chute DC motor overheated Chute DC motor over current Auto engage lever in automatic Auto engage mechanism ja...

Страница 24: ...al installation German Knife s obligation under this warranty is limited to a period of two 2 years from the date of original purchase Any Part covered under this warranty that is found by German Knife to have been defective within 2 years of the original purchase is limited to the repair or replacement including labor charges of defective parts or assemblies The labor charges shall include standa...