English
Newer PMX box (with RJ45 connector)
These PMX boxes offer wire plugs like the older ones which you can connect as described above.
We recommend using the RJ45 connector, though.
Select the black cable(s) with WD8 plugs on both ends.
1. Plug the end marked 'PrimuX' into the connector(s) on the back of your
PrimuX
controller
2. Connect the other end to your PMX box
If you need to build your own cable (i.e. a longer one) to connect to the RJ45 connector please
use the connection table below:
PrimuX
PIN 3 (green/white)
→
PMX PIN 4
PrimuX
PIN 4 (blue)
→
PMX PIN 1
PrimuX
PIN 5 (blue/white)
→
PMX PIN 2
PrimuX
PIN 6 (green)
→
PMX PIN 5
Other setups
If your setup differs from those described above please make sure that the connections are made
according to the table below:
PrimuX
PIN 3
→
TX (controller transmits)
PrimuX
PIN 4
→
RX (controller receives)
PrimuX
PIN 5
→
RX (controller receives)
PrimuX
PIN 6
→
TX (controller transmits)
Connectors
The
PrimuX
series offers controllers with more than one line per controller. The
PrimuX 2S0
II/E
for instance supports two lines, the
PrimuX 4S0 II/E
supports four and the
PrimuX 8S0
II/E
supports eight lines.
The images below can help you in identifying the connectors for each line. In these images ''C1''
means line 1, ''C2'' means line 2 and so on.
Connectors
43
Содержание PrimuX
Страница 1: ...PrimuX PROFESSIONAL COMMUNICATION...
Страница 2: ...Deutsch Installationsanleitung 1...
Страница 22: ...English Installation manual 21...
Страница 45: ...English PrimuX xS0 II PrimuX xS0 E PrimuX 4S2M xS2M II PrimuX xS2M E 44 Connectors...