Offline Operation
4-8
Disabling and Enabling Servo Power
Disabling and Enabling Servo Power
Disabling and Enabling Servo Power
Servo Disable removes power from the servo motors that control the
movement of the beam. This allows you to safely change the pen or cartridge,
or to move the beam/cartridge assembly by hand without loss of data or
position information.
When you enable the servo motors, the beam automatically moves to where it
was before you disabled the servos.
WARNING: A
LWAYS DISABLE SERVOS WHEN PERFORMING ANY TASK THAT
REQUIRES PUTTING YOUR HANDS NEAR THE PLOTTING AREA
.
F
AILURE TO DISABLE SERVOS MAY RESULT IN INJURY
.
T
O DISABLE SERVOS
1. From page one of the Offline menu, press the Menu key one time to
display page two.
2. From page two of the Offline menu, press
F3-S
ERVO
D
ISABLE
to remove
power from the servo motors.
Disabling the servos does not remove power to the plotter. All plot and
position data is kept intact.
From the Servo Disable menu you can restart the servos or reset the
plotter.
Resume returns the plotter to operation at the point where the servos
were disabled.
Reset returns the plotter to its initial power-on state. Any temporary
parameter settings will be returned to GGT default values.
SERVO DISABLE
RESUME
RESET