manualshive.com logo in svg
background image

September 2010

 

Manuale Operatore Piegatrice Mondial  

4

 

• 

Never remove covers or guards that are fastened with screws. There 
are no operator serviceable areas within these covers. 

• 

Never locate the equipment near a radiator or any other heat source. 

• 

Never push objects of any kind into the ventilation openings. 

• 

Never override or “cheat” any of the electrical or mechanical 
interlock devices. 

• 

Never operate the equipment if you notice unusual noises or odors. 
Disconnect the power cord from the electrical outlet and contact 
your local Service Provider immediately. 

 

Radio Frequency Emissions 

This equipment has been tested and found to comply with the limits for 
a class A digital device, pursuant to Part 15 of the FCC Rules and EN 
55022 standard for EMC rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment 
is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and 
used in accordance with the instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment in a 
residential area is likely to cause harmful interference, in which case the 
user will be required to correct the interference at his own expense. 

Changes and  modifications to this equipment not specifically approved 
by GERA void the user’s authority to operate this equipment. 

 

 

 

 

 

 

Product Safety Certification 

This product is certified by the following Agency using the Safety 
standards listed.  

Agency Standard 

UL  

UL60950-1,  1

st

  Edition (2006) 

DEMKO 

IEC 60950-1, 1

st

  Edition (2001) 

This product was manufactured under a registered ISO 9001 Quality 
system. 

 

Regulatory Information 

The CE mark applied to this product symbolizes GERA’s declaration of 
conformity with the applicable Directives of the European Union. 

A full declaration of conformity, defining the relevant directives and 
referenced standards, can be obtained from your Authorized Local 
Dealer.  

 

Environmental Compliance 

Directive WEEE 2002/96/CEE 

 

This symbol means the need to dispose the product 
according to the law in force in the own country. 
Before dispose the GERA product, mind that it 
contains lead and other materials that could require 
specific procedures for the disposing. The lead 
quantity is fully compliant with the international in 
force when the product was put on the market 

Содержание Mondial Series

Страница 1: ...GERA Cut Fold Operator Manual September 2010 ...

Страница 2: ...N 4 REGULATORY INFORMATION 4 ENVIRONMENTAL COMPLIANCE 4 WARRANTY 5 GENERAL OVERVIEW 5 FOLDER USE 5 BEFORE FOLDING 5 FOLDING OPERATIONS OVERVIEW 5 TRIMMER USE 6 Max trimming length 6 FAN FOLDING 7 CROSS FOLDING 8 JAMS REMOVALS 9 Manual Eject Procedure 9 Manual Removing 9 If The Jam Persist 9 SPECIFICATIONS 10 PAPER 10 ENVIRONMENT 10 MAXIMUM FOLDING LENGTH 10 TITLE BLOCK POSITIONS ACCEPTED 11 PROBLE...

Страница 3: ...n described Electrical Supply This product shall be operated from the type of electrical supply indicated on the product s data plate label If you are not sure that your electrical supply meets the requirements please consult your local power company for advice WARNING This product must be connected to a protective grounded circuit This product is supplied with a plug that has a protective groundi...

Страница 4: ...ded power outlet If in doubt have the outlet checked by a qualified electrician This equipment must be connected to a protective grounded circuit This equipment is supplied with a plug that has a protective grounding pin This plug will only fit into a grounded electrical outlet This is a safety feature To avoid risk of electric shock contact your electrician to replace the electrical outlet if you...

Страница 5: ...mmunications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes and modifications to this equipment not specifically approved by GERA void the user s authority to operate this equipment Product Safety Certification This product is certified by the following Agency u...

Страница 6: ...7 mm a b m p C only if the folder is provided with the table with sensor option at the moment not available Folder USE Before Folding Use the extractable support to put the drawings to be trimmed before folding operations Lift up the bar and block it in horizontal position Folding operations overview After put the drawings on the support bar trim the drawing edge short side where is located the ti...

Страница 7: ... the red line present in the transparent plate it correspond to a 5 mm trimming and perform the trimming 2 Perform the fan folding 3 Trim the copy just fan folded at the same way described in item 1 MAX trimming allowed here is 6 panels with 75 80 gsm weight paper 5 panels with 90 gsm weight paper 4 Perform the Cross Folding Max trimming length The maximum trimming length is 1260 mm if it is neede...

Страница 8: ...ce the copy in parallel to the folder Align the copy with the guides 914 A2 Title Block A3 A1 A0 Feed the copy with decision and wait that the folding process start If it is needed to fold long copies with roll 297 mm refer to the mobile guide at the folder entry Wait that the current folding process is over before feed the next copy otherwise the folder will emit a sound ...

Страница 9: ... folding E Take the fan folded copy with the title block up and front F Align the copy in comparison with the internal signs present ad the folder entry marked with the symbols that correspond to the measure 210 190 mm G That s advisable to perform manually a bit fold to the lower in the edge in order to help the feeding then finally feed advisable with decision the document Wait that the current ...

Страница 10: ...f the folder and pull the left lateral door then operate with the handle If The Jam Persist If the alarm persists this means that there are in the folder internal path paper strips residual it is necessary in this case feed and process a large and thick copy that manually ejected drags with it any paper strips residual Proceed as explained below 1 Check the upper folding pocket by feeding at the f...

Страница 11: ...per X 3 Environment Maximum folding length Fan Folding minimum length 410 mm Fan Folding maximum length 3500 mm Cross Folding maximum length 1500 mm 7 folds 15 C 32 C 60 F 90 F 3 35 85 RH3 Paper weight 75 80 90 gsm Paper not damaged or curled Feeling Edge 90 degrees trimmed ...

Страница 12: ...ale Operatore Piegatrice Mondial 11 Title Block positions accepted Feed the copy from the shorter side with the title block upper right Feed the copy from the bigger side with the title block upper left Butterfly Cut Fold ...

Страница 13: ... fed aligned enough Wait that the current folding process is over Repeat the feeding with a better alingment 4 The folder emits two beep each 30 seconds During the folding process a copy is jammed inside the folder Perform the jam removing procedure described in this manual 5 The folder often jams Paper curled or more than 90 gsm weight Use paper not curled and 75 80 90 gsm weight 6 The trimmer do...

Отзывы: