7.6 Output Setting
In the left menu, click
Output Setting
. This page appears.
Enable:
Select to enable this Output function to be used by GV-I/O Box.
Name:
Edit the name of the Output.
Output Mode:
Configure the input to
NC
(normally closed) or
NO
(normally open)
mode.
Normal Mode (N/O and N/C):
Output continues to be triggered until the source of
the output condition is stopped.
Toggle Mode (N/O and N/C):
Output continues to be triggered until a new input
trigger ends the output.
Pulse Mode (N/O and N/C):
Output is triggered for the amount of time set in the
Pulse Mode Delay Time (1-60)
field.
Pulse Mode Delay Time (1-60):
Enter the time in seconds for the pulse delay time
between 1 and 60 seconds.
Click the
Submit
button to save the changes, or click the
Cancel
button to return the
changes to its previous state.