Installation
21
6
Light Sensor Installation
1. Connect DNI and GND of the camera to the DNI and GND of the IR illuminator
(with light sensor).
2. On the OSD menu, select
Camera Setup
and set Day/Night Mode to
EXT
.
3. If the operating IR illuminator (with light sensor) is of high voltage (5 V), select
Camera Setup
and set DI/DO to
DI/H : DO/L
or
DI/H : DO/H
(both selections are
okay).
4. If the operating IR illuminator (with light sensor) is of low voltage (0 V), select
Camera Setup
and set DI/DO to
DI/L : DO/L
or
DI/L : DO/H
(both selections are
okay).
5. If the IR illuminator (with light sensor) works in conjunction with the IR illuminator
(of camera control), in which the light sensor will trigger the camera and then the
camera will trigger the IR illuminator, you need to set up DI/DO on the OSD menu
based on the operating voltage of the devices:
•
The operating IR illuminator (with light sensor) of high voltage (5 V) + the
operating IR illuminator (of camera control) of high voltage (5 V): select
Camera Setup
and set DI/DO to
DI/H : DO/H
.
•
The operating IR illuminator (with light sensor) of high voltage (5 V) + the
operating IR illuminator (of camera control) of low voltage (0 V): select
Camera Setup
and set DI/DO to
DI/H : DO/L
.
•
The operating IR illuminator (with light sensor) of low voltage (0 V) + the
operating IR illuminator (of camera control) of high voltage (5 V): select
Camera Setup
and set DI/DO to
DI/L : DO/H
.
•
The operating IR illuminator (with light sensor) of low voltage (5 V) + the
operating IR illuminator (of camera control) of low voltage (0V): select
Camera Setup
and set DI/DO to
DI/H : DO/L
.
For the OSD settings, see
8.2.3 DAY/NIGHT Setup
and
8.2 Sub Menu Description
.