WARRANTY

The EcoSense® pH100A/pH100M Instrument is warranted for one year 
from date of purchase by the end user against defects in materials and 
workmanship. pH100A/pH100M probes and cables are warranted for six 
months from date of purchase by the end user against defects in material 
and workmanship. Within the warranty period, YSI will repair or replace, at 
its sole discretion, free of charge, any product that YSI determines to be 
covered by this warranty.

To exercise this warranty, write or call your local YSI representative, or 
contact YSI Customer Service in Yellow Springs, Ohio. Send the product 
and proof of purchase, transportation prepaid, to the Authorized Service 
Center selected by YSI. Repair or replacement will be made and the 
product returned, transportation prepaid. Repaired or replaced products 
are warranted for the balance of the original warranty period, or at least 90 
days from date of repair or replacement.

Limitation of Warranty 

This Warranty does not apply to any YSI product damage or failure caused 
by: (i) failure to install, operate or use the product in accordance with 
YSI’s written instructions; (ii) abuse or misuse of the product; (iii) failure 
to maintain the product in accordance with YSI’s written instructions or 
standard industry procedure; (iv) any improper repairs to the product; (v) 
use by you of defective or improper components or parts in servicing or 
repairing the product; or (vi) modification of the product in any way not 
expressly authorized by YSI.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR 
IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE. YSI’s LIABILITY UNDER THIS WARRANTY 
IS LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, AND THIS 
SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY FOR ANY DEFECTIVE 
PRODUCT COVERED BY THIS WARRANTY. IN NO EVENT SHALL YSI BE 
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL 
DAMAGES RESULTING FROM ANY DEFECTIVE PRODUCT COVERED BY 
THIS WARRANTY

Contact Information

YSI
1725 Brannum Lane
Yellow Springs OH, 45387, USA
Tel: 800-897-4151 • 937-767-7241; Fax: 937-767-1058
E-mail: [email protected]
Web: ysi.com

Содержание 601031

Страница 1: ...USER MANUAL English EcoSense pH100A EcoSense pH100M pH mV and Temperature Instrument User Manual DOCUMENT 606030REF...

Страница 2: ...anty does not apply to any YSI product damage or failure caused by i failure to install operate or use the product in accordance with YSI s written instructions ii abuse or misuse of the product iii f...

Страница 3: ...Procedures 6 Buffer Set Selection 6 pH Calibration 7 Using the model pH160 Electrode Simulator 7 pH Measurements 8 Temperature Measurements 8 mV Measurements 8 Saving Viewing and Deleting Data 9 Downl...

Страница 4: ...Specifications 14 Instrument Only Specifications 14 System Specifications 14 General Specifications 14...

Страница 5: ...rs to remove all contaminants that may affect probe connections 3 Wait for unit and all connections to dry before reinstalling the battery and resuming operation 4 If the unit does not function correc...

Страница 6: ...ediately of any damage or missing parts Save all packing materials until satisfactory operation is confirmed B AT T E R Y I N S TA L L AT I O N An initial display of BAT on the LCD indicates approxima...

Страница 7: ...end point and lock the display to indicate the end point value of a measurement The pH100A and pH100M can also be used in non AUTOLOCK mode AUTOLOCK and user prompts help eliminate most errors in det...

Страница 8: ...displays 7 STAND SLOPE STAND or SLOPE remains steady if the parameter has been calibrated If either one has not been calibrated it flashes 8 AUTO Autolock mode indicator 9 Data set number 10 Temperat...

Страница 9: ...Effic ESC Recal Meas Press and hold Stand Recal while turning on the power to change the buffer set Press and hold Stand Recal for 2 seconds once the instrument is on to begin calibrating Press and h...

Страница 10: ...r 3 seconds will allow date and time information to be updated Pressing and holding for 6 seconds will allow for the date e g MM DD YYYY and time format 12 or 24 hour settings to be changed 8 EcoSense...

Страница 11: ...S 7482 C power symbol PMS 130 C logo Reverse white all other imagery EcoSe Mode Stand Slope Effic ESC Recal Meas to calibrate If AUTOLOCK is off the second point has been calibrated If AUTOLOCK is on...

Страница 12: ...display the sample temperature by pressing the up and down arrow keys 10 0 to 120 C If an ATC temp probe is connected ATC displays along with the sample temperature 3 If AUTOLOCK is off the pH value...

Страница 13: ...e Effic ESC Recal Meas ESC while that option is displayed If All is selected all records will be deleted from memory and None will be displayed Press Mode twice to return to the measurement mode If Ea...

Страница 14: ...rse white all other imagery pH EcoSense pH Mode Stand Slope Effic ESC Recal Meas key changes the display in the upper right corner to be either Date or Time Press and hold the Slope YSI EcoSense Handh...

Страница 15: ...ed to within 30 of the buffer value Buffer 4 00 4 01 9 18 or 10 01 is not correct Check that the correct buffer is used and that the electrode slope is not off by more than 30 from the theoretical slo...

Страница 16: ...perature of 31 1 is sometimes interpreted by Excel as 31 Jan when German is set as the PC language If a data file is opened in Excel and measurement data is incorrectly interpreted as something other...

Страница 17: ...placed on your opened spreadsheet A C C E S S O R I E S PA R T N U M B E R S Part Number Description 605377 pH Temp field probe with 1 meter cable 605378 pH Temp field probe with 4 meter cable 605374...

Страница 18: ...se specifications reflect the range and resolution that can be displayed on the instrument as well as the accuracy of the instrument electronics Parameter Range Resolution Accuracy Temperature 10 0 to...

Страница 19: ...Feature Yes Operating Range Temperature 0 to 50 C 32 to 122 F Operating Range Relative Humidity up to 95 ATC Probe Thermistor 10K at 25 C Dimensions L x W x D 18 9 cm x 7 9 cm x 3 8 cm 7 45 in x 3 10...

Страница 20: ...EC 61326 1 2012 IEC 61000 3 2 2005 IEC 61000 3 3 2008 IEC 61000 4 2 2008 IEC 61000 4 3 2006 IEC 61000 4 4 2004 IEC 61000 4 6 2008 IEC 61000 4 8 2009 Item 606030REF Revision E December 2017 For the lat...

Отзывы: