: If the .csv file is opened with Excel

®

 and the data is not 

formatted correctly (e.g. a temperature reading is interpreted as a 
date), please refer to the Troubleshooting section.

5.  The instrument can be disconnected from the computer. The original 

.csv file should still be located on the pH100M instrument. 

Recal Timer - pH100M Only

The Recal Timer feature provides a reminder to recalibrate the probe. 
If enabled, ‘Recal’ will be displayed when the user-defined interval has 
elapsed. 

Press and hold 

Stand/Recal 

for 6 seconds to access the Recal Timer input 

display. Use the Up and Down arrow keys to adjust the value for the recal 
prompt in number of days. Press 

YSI EcoSense Handheld Overlay

1/26/2016

 

pH100M

colors:

Black background

PMS 7482 C power symbol

PMS 130 C logo

Reverse white all other imagery

pH

100

M

ATC

EcoSense

®

pH

Mode

Stand

Slope

Effic.

ESC

Recal

Meas.

/ESC

 to confirm. The instrument will 

return to the run screen.

Any value between 0 and 60 days can be selected. Set the value to 0 to 
disable the Recal Timer. 

Date/Time Settings - pH100M Only

A short press (i.e. key is not held) of the 

Slope/

YSI EcoSense Handheld Overlay

1/26/2016

 

pH100M

colors:

Black background

PMS 7482 C power symbol

PMS 130 C logo

Reverse white all other imagery

pH

100

M

ATC

EcoSense

®

pH

Mode

Stand

Slope

Effic.

ESC

Recal

Meas.

 key changes the display 

in the upper right corner to be either Date or Time.

Press and hold the 

Slope/

YSI EcoSense Handheld Overlay

1/26/2016

 

pH100M

colors:

Black background

PMS 7482 C power symbol

PMS 130 C logo

Reverse white all other imagery

pH

100

M

ATC

EcoSense

®

pH

Mode

Stand

Slope

Effic.

ESC

Recal

Meas.

 key for 3 seconds to set date and time 

information. Use the up and down arrow keys to adjust Hour, Minute (Min) 
and Second (Sec). Press 

YSI EcoSense Handheld Overlay

1/26/2016

 

pH100M

colors:

Black background

PMS 7482 C power symbol

PMS 130 C logo

Reverse white all other imagery

pH

100

M

ATC

EcoSense

®

pH

Mode

Stand

Slope

Effic.

ESC

Recal

Meas.

/ESC

 to confirm each selection. After adjusting 

time, adjust date information by using the up and down arrow key to adjust 
the MM (month), DD (Day) and YYYY (Year) information. Press 

YSI EcoSense Handheld Overlay

1/26/2016

 

pH100M

colors:

Black background

PMS 7482 C power symbol

PMS 130 C logo

Reverse white all other imagery

pH

100

M

ATC

EcoSense

®

pH

Mode

Stand

Slope

Effic.

ESC

Recal

Meas.

/ESC

 to 

confirm each selection. 

Press and hold the 

Slope/

YSI EcoSense Handheld Overlay

1/26/2016

 

pH100M

colors:

Black background

PMS 7482 C power symbol

PMS 130 C logo

Reverse white all other imagery

pH

100

M

ATC

EcoSense

®

pH

Mode

Stand

Slope

Effic.

ESC

Recal

Meas.

 key for 6 seconds to set the date/time format. 

Use the Up and Down arrow keys to display the desired Date format (MM/
DD/YYYY, DD/MM/YYYY, or YYYY/MM/DD), followed by 

YSI EcoSense Handheld Overlay

1/26/2016

 

pH100M

colors:

Black background

PMS 7482 C power symbol

PMS 130 C logo

Reverse white all other imagery

pH

100

M

ATC

EcoSense

®

pH

Mode

Stand

Slope

Effic.

ESC

Recal

Meas.

/ESC

 to confirm 

the selection. Next, use the Up and Down arrow keys to display the desired 
Time format (12-hour or 24-hour), followed by 

YSI EcoSense Handheld Overlay

1/26/2016

 

pH100M

colors:

Black background

PMS 7482 C power symbol

PMS 130 C logo

Reverse white all other imagery

pH

100

M

ATC

EcoSense

®

pH

Mode

Stand

Slope

Effic.

ESC

Recal

Meas.

/ESC

 to confirm the 

selection.

Содержание 601031

Страница 1: ...USER MANUAL English EcoSense pH100A EcoSense pH100M pH mV and Temperature Instrument User Manual DOCUMENT 606030REF...

Страница 2: ...anty does not apply to any YSI product damage or failure caused by i failure to install operate or use the product in accordance with YSI s written instructions ii abuse or misuse of the product iii f...

Страница 3: ...Procedures 6 Buffer Set Selection 6 pH Calibration 7 Using the model pH160 Electrode Simulator 7 pH Measurements 8 Temperature Measurements 8 mV Measurements 8 Saving Viewing and Deleting Data 9 Downl...

Страница 4: ...Specifications 14 Instrument Only Specifications 14 System Specifications 14 General Specifications 14...

Страница 5: ...rs to remove all contaminants that may affect probe connections 3 Wait for unit and all connections to dry before reinstalling the battery and resuming operation 4 If the unit does not function correc...

Страница 6: ...ediately of any damage or missing parts Save all packing materials until satisfactory operation is confirmed B AT T E R Y I N S TA L L AT I O N An initial display of BAT on the LCD indicates approxima...

Страница 7: ...end point and lock the display to indicate the end point value of a measurement The pH100A and pH100M can also be used in non AUTOLOCK mode AUTOLOCK and user prompts help eliminate most errors in det...

Страница 8: ...displays 7 STAND SLOPE STAND or SLOPE remains steady if the parameter has been calibrated If either one has not been calibrated it flashes 8 AUTO Autolock mode indicator 9 Data set number 10 Temperat...

Страница 9: ...Effic ESC Recal Meas Press and hold Stand Recal while turning on the power to change the buffer set Press and hold Stand Recal for 2 seconds once the instrument is on to begin calibrating Press and h...

Страница 10: ...r 3 seconds will allow date and time information to be updated Pressing and holding for 6 seconds will allow for the date e g MM DD YYYY and time format 12 or 24 hour settings to be changed 8 EcoSense...

Страница 11: ...S 7482 C power symbol PMS 130 C logo Reverse white all other imagery EcoSe Mode Stand Slope Effic ESC Recal Meas to calibrate If AUTOLOCK is off the second point has been calibrated If AUTOLOCK is on...

Страница 12: ...display the sample temperature by pressing the up and down arrow keys 10 0 to 120 C If an ATC temp probe is connected ATC displays along with the sample temperature 3 If AUTOLOCK is off the pH value...

Страница 13: ...e Effic ESC Recal Meas ESC while that option is displayed If All is selected all records will be deleted from memory and None will be displayed Press Mode twice to return to the measurement mode If Ea...

Страница 14: ...rse white all other imagery pH EcoSense pH Mode Stand Slope Effic ESC Recal Meas key changes the display in the upper right corner to be either Date or Time Press and hold the Slope YSI EcoSense Handh...

Страница 15: ...ed to within 30 of the buffer value Buffer 4 00 4 01 9 18 or 10 01 is not correct Check that the correct buffer is used and that the electrode slope is not off by more than 30 from the theoretical slo...

Страница 16: ...perature of 31 1 is sometimes interpreted by Excel as 31 Jan when German is set as the PC language If a data file is opened in Excel and measurement data is incorrectly interpreted as something other...

Страница 17: ...placed on your opened spreadsheet A C C E S S O R I E S PA R T N U M B E R S Part Number Description 605377 pH Temp field probe with 1 meter cable 605378 pH Temp field probe with 4 meter cable 605374...

Страница 18: ...se specifications reflect the range and resolution that can be displayed on the instrument as well as the accuracy of the instrument electronics Parameter Range Resolution Accuracy Temperature 10 0 to...

Страница 19: ...Feature Yes Operating Range Temperature 0 to 50 C 32 to 122 F Operating Range Relative Humidity up to 95 ATC Probe Thermistor 10K at 25 C Dimensions L x W x D 18 9 cm x 7 9 cm x 3 8 cm 7 45 in x 3 10...

Страница 20: ...EC 61326 1 2012 IEC 61000 3 2 2005 IEC 61000 3 3 2008 IEC 61000 4 2 2008 IEC 61000 4 3 2006 IEC 61000 4 4 2004 IEC 61000 4 6 2008 IEC 61000 4 8 2009 Item 606030REF Revision E December 2017 For the lat...

Отзывы: