Geotech 0.675 Скачать руководство пользователя страница 22

 

20 

 

Section 5: System Troubleshooting 

 
 
 

 

 
 
 

Do not operate this equipment if it has been damaged, broken, smashed, or 
excessively worn.  Broken components pose a severe threat to the safety of the 
operator and his or her environment. Contact Geotech for any service or repair 
needs. 
 
Problem:

 Air in fluid line or flow cell. 

 
Solutions 

 

Ensure timer settings on controller prevent bladder from being over pressurized. 
Verify PTFE collar is in place at either end of the bladder. Inspect O-rings for 
damage and replace if needed. Inspect bladder for cuts and holes and replace if 
needed. 

 

Occasionally, significant amounts of dissolved gasses can be encountered in 
ground water, especially in deep well areas with significant hydraulic pressures. 
When this fluid is exposed to atmosphere, out-gassing may occur. Refer to your 
Standard Operating Procedure for specifics on dealing with this situation. 

 
Problem:

 Not pumping any fluid (or no air). 

 
Solutions: 

 

Verify the pump is below static water level. Inspect airline tubing for kinks, cracks 
or breaks. Make sure you are not getting leaks at any fittings. Replace damaged 
or worn tubing. Cut tubing back and re-terminate at leaking fitting joint. 

 

Problem:

 Not pumping any fluid (air is coming out fluid discharge line). 

 
Solutions: 

 

Disassemble pump and inspect the O-rings and bladder. Replace either or both if 
damaged. Verify the pump is below static water level. 

 

 

If you are experiencing other problems than mentioned above, please call Geotech 

Technical Support for immediate assistance, (800) 833-7958. 

 
 
 

Read and understand the portable generator and/or portable air 
compressor user manual for proper installation and operation and 
Earth grounding instructions. If using portable compressed gas tanks 
be sure to exercise proper caution and safety protection devices as 
outlined by the supplier and any additional safety requirements 
mandated by local jurisdiction. 
 

Содержание 0.675

Страница 1: ...Rev 05 25 2017 Part 11150323 Geotech Portable Bladder Pumps Installation and Operation Manual...

Страница 2: ......

Страница 3: ...4 Section 2 System Installation 6 Section 3 System Operation 8 Section 4 System Maintenance 13 Section 5 System Troubleshooting 20 Section 6 System Specifications 21 Section 7 Replacement Parts List 2...

Страница 4: ...proceed until you read and thoroughly understand the WARNING message WARNING CAUTION A raised hand icon indicates CAUTION information that relates to a situation or condition that could lead to equip...

Страница 5: ...ropriate gloves and be mindful of contaminated fluids contacting your person and entering the environment when operating any ground water sampling device WARNING The following applies only to users in...

Страница 6: ...via hydrostatic pressure The pump must be submerged to operate The bladder then fills with fluid Compressed air enters the space between the bladder and the interior of the pump housing The intake che...

Страница 7: ...Stainless Steel and is easily removable for field maintenance The intake filter screen protects and extends the life of the bladder material see Warranty Optional Drop Tube Intake Assembly An optiona...

Страница 8: ...ecifications of this manual for tubing sizes When using the 1 66 4cm diameter pump the larger diameter tube is for fluid and the smaller one for air Read the following before installation to prevent d...

Страница 9: ...in lowering the pump into the well especially when the well is not vertical or has come out of alignment for any reason Optional Drop Tube Assembly If a Drop Tube Intake assembly is employed a third t...

Страница 10: ...ring pumping and start to increase after all of the water has been evacuated from the pump If you notice the pressure increasing after a pump cycle reduce DISHCARGE TIME Using the Example Flow Rates s...

Страница 11: ...irline 150 ft 46 m airline 3 ft 0 9 m submergence Pump Size Discharge Tube Size Flow Approx Geocontrol PRO Settings Fill Time Discharge Time 1 66 x 36 4 x 91 cm 1 4 ID x 3 8 OD 64 x 127 mm 9 oz min 26...

Страница 12: ...in 0 43 cm 0 3 in 5 cm 3 in 50 cm 15 in 246 cm 30 in 492 cm 75 in 1230 cm 150 in 2460 cm 0 25 in 0 64 cm 0 6 in 10 cm 6 in 100 cm 30 in 492 cm 60 in 984 cm 150 in 2460 cm 300 in 4920 cm Air Volume of...

Страница 13: ...11 Figure 3 1 Tank Volume vs BP Consumption...

Страница 14: ...s mentioned above the additional 10 PSI 0 7 bar is to account for the pump itself and friction loss along the airline tubing When the length of the airline is 50 15m or less there is no need for the a...

Страница 15: ...by turning the housing counter clockwise Use your hand or a strap wrench If the pump does not easily come off use the wrench flats on the cap to provide leverage The housing should twist slide off DO...

Страница 16: ...4 Pulling from the lower end of the bladder 18 21150054 36 21150141 slide the bladder off the internal center tube weldment assembly Figure 4 4 Removal of Bladder 5 Remove all O rings If needed use a...

Страница 17: ...Check Ball from the inside of the Bottom Intake Assembly 3 Remove all O rings on the assembly If needed use a flat object to help the O rings out of the grooves on the Bottom Intake Assembly Do not ov...

Страница 18: ...e Assembly 3 Insert the SS Check ball into the Bottom Intake Assembly 4 Push the Check Ball Retainer in ensuring the O ring is no longer visible Bladder Reassembly 1 Install O ring 11150318 on the cap...

Страница 19: ...50054 36 21150141 onto the internal center tube weldment assembly over the O ring 11150319 on the bottom end of the center tube assembly and then over the O ring 11150319 on the upper end of the cente...

Страница 20: ...he bladder secured by the Compression Ring 21150042 slide the second compression ring over the end of the bladder until the O ring is visible in the middle of the Compression Ring Figure 4 15 Bottom C...

Страница 21: ...t into the bottom of the pump Be sure the bottom intake assembly is sealed against the outer housing Figure 4 17a Incorrect Installation Figure 4 17b Correct Installation Inspect O rings and bladder f...

Страница 22: ...pecifics on dealing with this situation Problem Not pumping any fluid or no air Solutions Verify the pump is below static water level Inspect airline tubing for kinks cracks or breaks Make sure you ar...

Страница 23: ...00 g 376 g Volume Cycle 11 oz 5 oz 1 oz 0 5 oz 310 mL 150 mL 29 mL 15 mL Min Well I D 2 2 1 75 50 mm 50 mm 25 mm 19 mm Min Operating Pressure 5 psi ash 3 bar Operating Pressure 100psi 7 bar Proof Pres...

Страница 24: ...to 500 152m of water column Special care must be taken to avoid burns and exposure to out gassing of volatiles when pumping fluids at elevated temperatures Special air source considerations need to be...

Страница 25: ...23 Section 7 Replacement Parts List 1 66 Bladder Pump Components 18 model shown...

Страница 26: ...SFTY CB CE 51150068 10 1 CAP UPPER WELDMENT SS 1 66 18 PBP CE 21150091 10 CAP UPPER WELDMENT SS 1 66 36 PBP CE 21150136 11 1 PLUG BALL RETAINER 1 66 PBP CE 21150096 12 1 O RING VITON 014 17500119 13 1...

Страница 27: ...25 Sold Separately 850 Bladder Pump Components...

Страница 28: ...850 BP 21150047 10 1 ASSY BOTTOM INTAKE 85 BP 51150118 11 1 CAP LOWER SS6 850 BP 21150046 12 1 SCREEN INTAKE SS6 85 BP 21150050 13 1 DISC PTFE 85 BP 21150049 14 1 RING SNAP SS6 INTERNAL 85 BP 11150053...

Страница 29: ...27 675 Bladder Pump Components...

Страница 30: ...120 10 1 RETAINER BALL 675 BP TACO 21150087 11 1 BALL SS6 1 4 17500079 12 1 CAP LOWER SS6 675 BP 21150031 13 1 SCREEN INTAKE SS6 675 BP 11150317 14 1 DISC PTFE 675 BP 21150033 15 1 RING SNAP SS 675 BP...

Страница 31: ...n flow rate examples SP 12 08 15 Corrected Drop Tube tubing size for 1 66 models SP 1 11 2016 Project 1482 Section 2 added note about 1 66x36 model requiring BP Controller 300 for full bladder volumes...

Страница 32: ...30 Notes...

Страница 33: ...f manufacture 2010 Conform to the protection requirements of 2006 42 EC Machinery Directive by application of the following standards EN 809 A1 AC 2010 EN 61010 1 2010 Year of affixation of the CE Mar...

Страница 34: ...al Authorization number RMA is required prior to return of any equipment to our facilities please call our 800 number for appropriate location An RMA will be issued upon receipt of your request to ret...

Страница 35: ...303 322 7242 email sales geotechenv com website www geotechenv com In the EU Geotech Equipos Ambientales Calle Francesc I Ferrer Guardia Local 19 Mollet del Valles Barcelona 08100 Espa a Tlf 34 93 54...

Отзывы: