2. Install O-rings (#11150332 & #1110318) in the grooves on the Bottom Intake
Assembly.
Ensure that O-rings are not twisted.
Figure 4-9:
O-rings on the Bottom Intake Assembly
3. Insert the SS Check ball into the Bottom Intake Assembly.
4. Push the Check Ball Retainer in ensuring the O-ring is no longer visible.
Bladder Reassembly:
1. Install O-ring (#11150318) on the cap of the center tube weldment assembly.
Figure 4-10:
Cap O-ring
SS Check
Ball must be inside the Bottom Intake
Assembly.
The configuration shown may damage pump.