32
Notes for Radio Usage
1.
The RF power switch of transmitting radio selects high power output in the
HIGH position while the action range can be as good as 10km, selects low power
output in the LOW position while the action range is within 3km.
2.
The input voltage range of PDL transmitting radio and receiving radio: 10.5V -
16V, and the standard input voltage is 12V.
3.
The PDL enclosure is rugged extruded aluminum with integrated heat sink fins.
The enclosure is painted with weather resistant powder coat blue paint. Black
bumpers are integrated with front and rear gaskets to provide shock protection
and watertight operation. The enclosure is not designed to withstand submersion
and must not be allowed to sit in standing water.
4.
The PDL enclosure and heat sink may become very hot during operation. This is
normal depending on the ambient temperature, RF power selection and
transmission duty cycle. Turn off the unit and allow it to cool prior to handling.
5.
In the receiving radio has a built-in charger that monitors and controls the
charging of the internal battery. The internal battery quickly charges in less than 4
hours, and can be charged with the supplied charger, or from an external 12 volt
supply. We recommend charging the internal battery at room temperature.
Charging is inhibited if the ambient temperature is below 0° C or above 40° C.
Содержание eFix R1
Страница 1: ...eFix R1 Hardware Operating Instructions Wuhan Geosun Information Technology Co Ltd...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 28: ...22 ControllerConnecting standard GeoRef K2 GeoRef K2 Controller Connecting C H AP T E R 4...
Страница 31: ...25 Common Troubleshooting eFix R1 Common Troubleshooting C H AP T E R 5...