background image

© 2019 GeoSLAM Ltd 

ZEB‐HORIZON User Manual v1.2 

 

 

 

 

  

  2

 

SAFETY 

 

 

 

The ZEB‐HORIZON should only be used by trained operators. Always follow basic safety precautions when 
operating the ZEB‐HORIZON  to reduce the risk of personal injury and to prevent damage to the equipment.  Do 
not operate the equipment with suspected defects or obvious mechanical damage. Please refer all servicing of the 
equipment to qualified service personnel. Only use the components and accessories supplied with your system or 
other accessories recommended by GeoSLAM Ltd. Before operating the system for the first time please read this 
manual in full. 

The equipment contains sensitive electrical and mechanical parts and thus requires appropriate handling. Do not 
bend or pull the cables forcibly. Never push objects of any kind into the connectors or sockets. Keep the equipment 
out of the reach of children. Under no circumstances should any modifications be made to the ZEB‐HORIZON 
without prior written permission from GeoSLAM Ltd. 

 

 

The ZEB‐HORIZON incorporates a Velodyne Puck VLP‐16 laser scanner. The VLP‐16 is 
classified as a CLASS 1 Laser Product in accordance with IEC 60825‐1:2007 & 2014

Equipment classification and requirements. 

Class 1 Laser Products are safe under 

reasonably foreseeable conditions of operation, including the use of  optical 

instruments for intra‐beam viewing. 

 
 

 

The ZEB‐HORIZON meets or exceeds the following standards: 

EN61326‐1:2013 Electrical equipment for measurement, control and laboratory use ‐ EMC requirements ‐ 
Industrial Location Immunity ‐ (immunity section only) 

EN61326‐1:2013 Electrical equipment for measurement, control and laboratory use ‐ EMC requirements ‐ Group 
1, Class A equipment ‐ (emissions section only) 

CFR 47 Code of Federal Regulations: Pt 15 Subpart B‐ Radio Frequency Devices ‐ Class A Unintentional Radiators 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when 
the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio 
frequency energy. If not installed and used in accordance with the instruction manual this may cause harmful 
interference to radio communications. Operation of this equipment in a residential area may cause interference. 

 

DO NOT attempt to dismantle the battery. 

DO NOT short circuit the battery. 

ONLY use the charger supplied with the system. 

Excess heat will degrade the battery rapidly. Always store the battery in a cool dry place. DO NOT leave for long 
periods in the sun or in a hot vehicle. 

The battery is splash proof but not water proof – do not immerse in water. 

 

 

When the ZEB‐HORIZON reaches the end of its life‐cycle please dispose of the equipment in 
accordance with Directive 2002/96/EC on Waste Electrical and Electronic equipment (WEEE). 

 

GeoSLAM Ltd is prepared to take back the waste equipment and accessories free of charge at the 
manufacturing unit in Ruddington, UK for proper treatment with the objectives of the WEEE. 

 
 

2.3 

ELECTROMAGNETIC COMPATABILITY 

2.1 

GENERAL SAFETY 

2.2 

LASER SAFETY 

2.4 

BATTERY SAFETY 

2.5 

SYSTEM DISPOSAL 

Содержание ZEB-HORIZON

Страница 1: ...2019 GeoSLAM Ltd 1 ZEB HORIZON User Manual v1 2 Copyright ZEB HORIZON User s Manual 2019 GeoSLAM Ltd All rights reserved ZEB HORIZON User Manual...

Страница 2: ...the raw scan data 8 3 4 File naming 9 3 5 Shutting down 9 Usage Guidelines 11 4 1 The environment 11 4 2 Loop closure 11 4 3 Transitioning between environments 11 4 4 Walking speed 12 4 5 Minimum and...

Страница 3: ...mperature 0o C to 50o C Ingress protection IP54 Power supply 14 8VDC 1 5A Weight Scanninghead withhandle 1 49kg Datalogger 0 72kg Battery 0 55kg Carry case and contents 4 2kg Dimensions Scanning head...

Страница 4: ...HORIZON hand held laser scanner 2 GS_610096 ZEB HORIZON data logger 3 GS_610098 ZEB HORIZON main cable 4 GS_USB USB memory stick 5 PAG_ Battery charger and power supply unit 6 MUS_ Data logger should...

Страница 5: ...s Industrial Location Immunity immunity section only EN61326 1 2013Electrical equipment for measurement control and laboratory use EMC requirements Group 1 Class A equipment emissions section only CFR...

Страница 6: ...removable handle or can be mounted to mobile platformusing threaded mounting points see Section7 2 or the optionalmounting plate Contact GeoSLAM by any of the following methods Phone 44 1949 831814 E...

Страница 7: ...onnecting the hardware Ensure battery is charged and connected to data logger Connect the ZEB HORIZON main cable to the socket on the side of ZEB HORIZON scanner head Connect the other end of the ZEB...

Страница 8: ...ted as shown in Figure 3 1 Figure 3 1 To download the raw scan data power on the ZEB HORIZON data logger if not already powered on Connect the suppliedUSBmemoryUSBsocketonthedataloggerfrontpanel TheAU...

Страница 9: ...ZEB HORIZON data logger down long press the power button until two beeps are emitted The REVO and DATA LED s on the data logger will alternate RED until the system powers down Do not turn the data lo...

Страница 10: ...flash Single RED flash Laser sensor not detected Double RED flash Double RED flash IMU sensor not detected Triple RED flash Triple RED flash Laser and IMU sensors not detected ORANGE ORANGE Datalogger...

Страница 11: ...ns or vehicles as the SLAM algorithm may lock on to these objects as static features TheSLAMalgorithmused toprocess the rawscandataintoapointcloud uses a method analogous tothe Traverse technique used...

Страница 12: ...oken down into more than one scan mission This is to avoid very largefilesizesaswellasreduceanydriftthatmightbecreatedinthedata Itisrecommendedthateachsurveyis limitedto30minutes Atslowwalkingpace iti...

Страница 13: ...sed todownloadthe filefromthedataloggertoa suitable folder on the PC running GeoSLAM Hub and extract the dot geoslam file YYYY MM DD_hh mm ss geoslam Toextractafilefromazipfilerightclickonthezipfilean...

Страница 14: ...sed dataset clickthe VIEWbuttonnexttothe file namein the datasetlist A 3D viewof the dataset opens in a new GS View window Figure 5 3 Further instructions for data export and the other post processing...

Страница 15: ...er from the battery and from the AC mains Do not leave the charger connected to the battery for long periods after the battery is charged A single button press of the display button on the side of the...

Страница 16: ...hebatteryissplashproofbutnotwaterproof donotimmerseinwater The battery has been tested and passed section 38 3 of the UN Manual of Tests and Criteria UN Transportation Testing as required by the IATA...

Страница 17: ...2019 GeoSLAM Ltd 17 ZEB HORIZON User Manual v1 2...

Страница 18: ...he Drive letterforthe USB memorystick see Figure 7 1 andcheck the tickboxagainstthe task you want to perform To Download Specific Files enter the date of the required files YYYY MM DD The example in F...

Страница 19: ...2019 GeoSLAM Ltd 19 ZEB HORIZON User Manual v1 2 7 2 APPENDIX 2 DIMENSIONAL DRAWINGS...

Страница 20: ...2019 GeoSLAM Ltd 20 ZEB HORIZON User Manual v1 2...

Отзывы: