background image

Getting Started

Initialising

The data logger is password protected and needs to be 
initialised before use. Each data logger has a different 
password (code) which is required for erasing and initialising.

Please keep the code in a safe place as it is always required 
for erasing the memory. 

Pull to remove the waterproof cap and connect the data 
logger to a USB socket of a USB host enabled device (PC, 
tablet, etc), to guarantee waterproofness make sure that a 
layer of silicon grease is always present on the o-ring.

The data logger will appear like a USB disk storing three files: 
and DATALOGS.CSV, CONTROL.TXT, and CALIBRAT.TXT. 
Open the file CONTROL.TXT with a simple text editor. If your 
system does not have a native text editor please install one 
before using the logger. We have tested Notepad on 
Windows, Gedit on Ubuntu, and Ted on Android 4.0.

Please note that some Android devices have no host 
capability, others do not immediately open USB drives and 
require a specific app to manage USB drives, check with 
device specifications for USB Host capability.

The latest Mac versions can open the logger in read only 
mode an error message is shown “Cannot repair disk”: 
however this logger works up to Snow Leopard. In this case 
Mac users should install a “Virtual Machine” (VirtualBox) that 
can be downloaded for free and run a Snow Leopard image or 
a  free Linux image or a Windows one to program the device. 
However the logger remain fully readable by the latest Macs 
OS Versions: Data can be downloaded (sampling will resume 
once the device is unplugged, excluding millisecond 
sampling).  

Geosignal XP 101K USB Data Logger
Copyright 2017-2018 all rights reserved
www.geosignal.com.au

6

Содержание XP 101K USB

Страница 1: ...Geosignal Dataloggers XP 101K USB Version 1 0 1 User Manual...

Страница 2: ...Geosignal XP 101K USB Data Logger Copyright 2018 all rights reserved www geosignal com au 2...

Страница 3: ...tents INTRODUCTION 4 GETTING STARTED 6 MEMORY STRUCTURE 13 CALIBRATION 17 TROUBLESHOOTING 20 TECHNICAL SPECIFICATIONS 21 Geosignal XP 101K USB Data Logger Copyright 2018 all rights reserved www geosig...

Страница 4: ...versampling resolution Double calibration for maximum precision Multiple starts with separate timestamps for each sampling section Text file output compatible with common software like Open Office and...

Страница 5: ...e named DATALOGS CSV The data logger will start scan at the given time with the given scan rate after it will be detached from the USB socket Geosignal XP 101K USB Data Logger Copyright 2017 2018 all...

Страница 6: ...tall one before using the logger We have tested Notepad on Windows Gedit on Ubuntu and Ted on Android 4 0 Please note that some Android devices have no host capability others do not immediately open U...

Страница 7: ...50 Bar 0000 Bt50 Edit values save file to program them Do not change position length of fields Detach and plug device to show actual programmed values Log starts at Start Time after device is detached...

Страница 8: ...OL TXT Please NOTE we have found that after the data logger has been connected to a USB socket all the different operating systems we have tested read the file just ONCE CONTROL TEXT IS CASE SENSITIVE...

Страница 9: ...h a separate command please see the below millisecond scan rate paragraph Downloading Data Connect the data logger to any USB socket of a computer If the logger shows SCAN RATE pgm that indicates it i...

Страница 10: ...by the data logger when it is inserted into the USB socket The charge percentage is shown as Bt 99 in the file CONTROL TXT and it is worked out from the battery voltage which may not reflect the real...

Страница 11: ...tton located at the top of the USB plug inside the logger After that the file CONTROL TXT of the data logger will show that the current time has been reset and needs to be reprogrammed Geosignal XP 10...

Страница 12: ...010 00 PSI 0000 and saving the CONTROL TXT The data logger will restart Close and reopen the file CONTROL TXT it will show SENSOR 145 04 PSI 0000 Millisecond Scan Rate The datalogger can scan at fast...

Страница 13: ...ns the data If it is empty its length is zero CLAIBRAT TXT show the calibration constants and other parameters CONTROL TXT once opened with a text editor like notepad will appear as follow GEOSIGNAL U...

Страница 14: ...ou to unmount the data logger UNIX command or to go through the process of Safely remove the drive before the data is actually programmed into the data logger The data logger features a red LED to inf...

Страница 15: ...the starting time is past and not being used CLOCK 000 indicates the clock calibration in or seconds per week and can be changed to adjust the internal clock if it is running fast or slow SENSOR 050 0...

Страница 16: ...rks the measurement units BAR in this case The values of an existing file are automatically converted in PSI when the logger is set to operate in PSI All fields are separated by a comma and the period...

Страница 17: ...hown because of calculation and errors the logger cannot measure negative values depression To compensate for zero and gain errors XP 101K can be programmed with the following The offset calibration c...

Страница 18: ...o shows the equivalent values in term of pressure when applicable Calculating Offset and Scale Please note that the offset does not correspond to the output of the instrument at zero pressure as the s...

Страница 19: ...eed of scale calibration a ratio smaller than 1 000 indicates that the gain needs to be lowered a ratio greater than 1 000 indicates that the gain needs to be increased For Example analysing some data...

Страница 20: ...make sure device is unmounted or Safely removed Datalogger is connected but an error is produced when downloading data file Erase memory Measures downloaded are inconsistent Change the operating rang...

Страница 21: ...pling interval 1 500msec 1 sec 10 sec 1 min 10 min 1 hour 1 day Software No Not required Operating Temp C 40 85 C excluding battery Compensated Temperature C Type A 0 C to 50 C Type B 0 C to 55 C Medi...

Страница 22: ...K A 250 PSI 17 2 BAR XP 101K B range ranges 100 PSI 6 88 BAR 250 PSI 17 2 BAR 1000 PSI 68 8 BAR 5000 PSI 344 BAR 10000 PSI 688 BAR Geosignal XP 101K USB Data Logger Copyright 2017 2018 all rights rese...

Страница 23: ...ising 6 Introduction 4 LED 8 Macintosh Users 6 Memory Structure 13 Millisecond Scan Rate 12 15 Negative pressure 17 Offset 15 17 Order Code 22 Programming 8 Read inputs in real time 12 Reset 11 Scale...

Страница 24: ...Geosignal TM www geosignal com www geosignal com au support geosignal com PO BOX 2418 Warwick WA 6024 Australia...

Отзывы: