9
V1.4 March 15
5.0 QJ sectios contd..
QJ INCLINOMETER CASING SHOULD BE
INSTALLED WITH THE MALE END
DOWNWARDS
Lengths of Casing should be joined together as follows:-
STEP 1
Place male end into female end with locating peg on the
male end aligned with the keyway on the female end.
THE FEMALE END HAS A FACTORY
GREASED O-RING. CARE SHOULD BE
TAKEN TO PREVENT EITHER END OF THE
CASING BECOMING CONAMINATED WITH
DEBRIS WHICH WILL AFFECT THE SEAL
STEP 2
Push home the male joint into the female until it has
“snapped” together (the load required to snap together is
approximately 37 KgF)
ONCE QJ INCLINOMETER CASING IS
“SNAPPED” TOGETHER IT
CANNOT BE UNDONE