It is VITAL that personnel responsible for the installation and use of the
Geosense
®
HLC
-
6000 Series Hydraulic Anchor Load Cells READS and
UNDERSTANDS the manual, prior to working with the equipment.
**********
As stated before, it is vital to check all the equipment in the shipment soon
after taking delivery and well before installation is to be carried out. Check
that all components that are detailed on the shipping documents are
included.
5.0
INSTALLATION
This section of the manual is intended for all users of
HLC
-
6000 Series Hydraulic Anchor
Load Cells
manufactured by
Geosense
®
and is intended to provide guidance with
respect to their installation.
5.1
General Issues
•
Note serial number against location
•
Mark cables for future identification. Use an appropriate coding system and mark
cables at frequent intervals, not just at the ends.
•
Protect the ends of the signal cable. Cables should be terminated at a waterproof
box or with waterproof connectors.
5.2 General considerations
Ensure that the internal diameter of the cell is correct for the anchor strands or bolt
head.
Ensure that the capacity of the cell is sufficient for the anchor including the
tensioning.
Provide support brackets where necessary to ensure the load cell is kept centralised
during installation.
5.3 Mounting surfaces
Mounting surfaces should be flat and parallel for optimum performance the
mounting surface MUST be flat and perpendicular toi the direction of loading
(anchor or rod). Very stiff abutment plates and load distribution plates is
recommended.
The abutment plate (provided locally) is normally made to suit specific site
requirements and the load distribution plate (supplied by Geosense) should be I
inserted between the load cell and the anchor head (see next page)
Содержание HLC 6000 Series
Страница 1: ...V1 0 July 2020 I N S T R U C T I O N M A N U A L HLC 6000 SERIES HYDRAULIC ANCHOR LOAD CELLS...
Страница 2: ...2 V1 0 July 2020...
Страница 17: ...17 V1 0 July 2020 6 5 CALIBRATION Vibrating Wire...
Страница 18: ...18 V1 0 July 2020 6 5 CALIBRATION contd Pressure gauge Manometer...
Страница 26: ...26 V1 0 July 2020 VIBRATING WIRE ANCHOR LOAD CELLS HLC 6000 SERIES...